5
ENGLISH
GB
4.4.
Protection devices
The device is equipped with the following
protection systems:
A. Safety thermocouple
: it blocks the gas
supply if the flame goes out.
B. Safety thermostat:
it blocks the gas supply in
case of overheating (only for chromed
versions).
C. Gas supply tap
: to open and close the gas
line.
Check daily that the protection
devices are mounted correctly and
operational.
If the safety thermostat is released, the initial work
settings of the device must be set again in the
same position.
1.
Leave the griddle plate to cool down.
2.
Open the door (
D
).
3.
Press the safety thermostat button (B), to
activate the gas supply again.
4.
Close the door (
D
).
When using the devices with two griddle plates, in
order to detect the working thermostat, check
which burner is not working and press the button
of the appropriate thermostat.
4.5.
Index plate
The rating plate shown in the drawing is fixed
directly on the device. It includes all guidelines
and information required for safe use.
1)
EAN number
2)
Art. no./ model no. / CE certificate no.
3)
Category of device / type of design
4)
Power / gas consumption / Factory setting
for specified gas type
5)
Heat load
6)
Production date
7)
Series no.
8)
CE Declaration of Conformity
9)
WEEE symbol
A
B
C
D
A
Protection
device
1
2
8
3
4
6
7
5
9