Installation and operation
104609
17 / 32
EN
• Depending on the season (summer or winter), the probe may change the
maximum produced amount of ice. To change the probe setting, follow the
indication in chapter
'Setting Probe in Storage Container'
.
Operation Status / Alarm Status Indicators
The control key features the combination of white and red colour; colours indicate
operation status or alarm status:
Indicator / Alarm
Red LED
indicator
White LED
indicator
(AL03) No water alarm
ON 3"
blinks 1x
(AL04) Storage container probe damage
alarm
blinks 3x
ON 3"
(AL05) Regular maintenance indication
ON 3"
ON 3"
(AL06) High temperature condensation
ON
OFF
(AL07) Condenser probe damaged
blinks 4x
ON 3"
(AL08) Evaporator probe damaged
blinks 5x
ON 3"
(AL09) Alarm blackout
OFF x 1"
ON 5"
(AL10) Maximum pressure alarm
ON
OFF
(AL11) Drain pump alarm (optionally)
blinks 1x
blinks 1x
(AL14) Condenser cleaning preliminary
alarm
blinks 7x
ON 3"
(AL15) Inverted probes
blinks 5x
blinks 2x
(AL16) IR probe damaged
blinks 3x
ON 3"
(AL17) Evaporator high temperature alarm
ON 3"
blinks 2x
(AL18) Evaporator low temperature alarm
ON 3"
blinks 4x
(AL19) Augur motor thermal alarm 1 /
(AL21) Hall sensor alarm 1
1 x 3.0"
5 x 0.5"