- 35 -
7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
PROBLEM
CAUSE
REMEDY
The device is turned
on but the control
light (brewing
indicator) has not
come on.
•
Plug not connected
correctly.
•
Fuse of mains opened.
•
Control lamp defect.
•
Switch defect.
•
Connect plug correctl.
•
Control fuse, test
machine on other plug.
•
Contact supplier.
•
Contact supplier.
Coffee machine is
turned on but does
not function.
•
Coffee machine is
overdue a
decalcification.
•
Pull plug and let coffee
machine cool off, press
RESET-button on the
back of the machine.
Decalcify machine.
The coffee machine
shuts off.
•
Overheating protection
was triggered.
•
Thermostat defect.
•
Pull plug and let the
coffee machine cool off.
Press the RESET button
on the back of the
machine.
•
Contact supplier.
The device is turned
on, the brewing
indicator is on, but hot
water is not flowing
out.
•
Heating element defect.
•
Thermostat defect.
•
Contact supplier.
•
Contact supplier.
The device is turned
on, the brewing indi-
cator does not come
on and hot water
does not flow out.
•
Control panel is
damaged.
•
Damaged filling switch.
•
Contact supplier.
•
Contact supplier.
When turned on a fuse
immediately burns out.
•
Short-circuit.
•
Contact supplier.