5.2 Installation
Place the scale horizontally and change the battery switch to suitable model, then keep
the bubble inside of bubble level is aligned with the red circle.
Correct
Incorrect
5.3 Operation and explanation of the indications of the display
Turning on
When power is turned on (main switch „
“, then press „
“ key on the keypad, all
display segments appear on LCD for a few seconds and finally „0“ will appear on the
display.
The „
“ switch for the backlight is located at the left side of the bottom of the
scale. If the backlight is turned on the backlight of the display will light up as soon as an
object is placed on the weighing platform.
Select the weighing unit with UNIT.
Press „g/lb“ key to select a weighing unit e.g. „kg“, „g“, „oz“, „lb“.
Once the unit has been selected, the selected unit will be displayed to the weight value.
Weighing
If you do not use a container for weighing
Verify the reading is „0“. If not, press „
“-key to display „0“.
Place objects on the weighing platform to weigh.
When the reading becomes stable, the stable indicator “
“ is displayed.
If you use a container for weighing
Place an empty container on the weighing platform.
Wait for the stability indicator „
“ to be displayed and press „
“ key.
Place the objects to be weighed in the container.
When the reading becomes stable, the stable indicator „
“ is displayed.