- 47 -
7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Problem
Cause
Solution
The device is
connected to the power
supply but the green
indicator is off and the
device does not heat.
The plug is not properly
connected to the socket.
Safety fuse disconnected
Control box is not
properly mounted
The overheating protect-
tion has been activated.
No contact with a micro-
switch
Remove the plug and insert
properly into socket.
Check fuse, connect
device to another socket.
Check mounting of the
control box
Press
RESET
button in the
control box.
Contact the service
company.
The heating indicator is
on but temperature does
not rise.
Interrupted contact with
the heating element.
Damaged heating
element.
Contact the service
company.
Contact the service
company.
The green power supply
indicator is on but
despite setting the
temperature the orange
heating indicator is off.
The preset temperature
has been reached.
Damaged temperature
controller.
Damaged indicator light.
Check operation after the
temperature set point
change.
Contact the service
company.
Contact the service
company.
The device stops
heating after some
time.
The overheating
protection has been
activated.
Press
RESET
button in the
control box.
If the overheating protection
activates again within a
short time, contact the sales
agent
If you cannot remove the malfunctions:
-
do not open the body,
-
notify the customer service point or contact the sales
agent, while providing the following information:
type of malfunction;
article and serial number (rating plate at the rear of the device).