Installation Instructions
18 / 32
1583011
EN
5.3
Gas Connection
• Gas supply connection may be executed exclusively by a qualified gas fitter
according to the current regulations.
• Installation locations available in public should follow accident prevention
regulations and safety norms with respect to fire occurrences and panic.
• The appliance is approved and by factory default prepared to operate with the
type of gas stated on the rating plate. Before commencing installation, check if
local gas supply (gas type and pressure) is concurrent with the default setting of
the appliance.
• Depending on type of gas, the intersection of gas supply line must be selected
according to regulations in force and properly installed.
• The connection may be established as fixed or detachable; if flexible tubes are
used, they must be made of stainless steel, pursuant to DIN 3383 Part 1 or
3384.
• If threaded connections are used with sealants or sealing materials, they must
be tested and approved by DVGW.
• Gas connection stub is found at the back of the appliance, and is marked with
the symbol of
.
• Make sure that gas connection line is protected against coming in contact with
hot elements of the oven.
• All connection points between the installation and the appliance must be subject
of tightness check. For gas line tightness check always use soap solution or a
special foaming agent for detecting leakages.
• Connection points should be covered with an agent — no air bubbles should be
produced. Also the gas cut-off valves should be subject of this check.
ATTENTION!
Do not use open fire to test tightness!
Summary of Contents for 1583011
Page 1: ...Flex 7360 1583011 ...