Installation Instructions
1505393
15 / 28
EN
– sufficiently large, and thus enabling usage of the appliance with no
problems;
– easily accessible;
– well ventilated.
• Maintain sufficient clearance from table edges. The appliance might turn over
and fall down.
• Maintain minimum clearance of 15 cm from walls and objects at both sides and
at the rear, as well as 50 cm over the appliance.
5.2
Gas Connection
• Before establishing the connection to gas installation, make sure that the
appliance is set to gas type and pressure available in the installation location
(see rating plate on the appliance and packaging, as well as Tables 1 and 2 in
sections
'Technical Data'
).
• A certified gas cut-off valve must be installed in an easily accessible location
between the gas supply installation and the appliance, so that, if needed, gas
supply may be interrupted at any time.
• Make sure that the gas cylinder (if applicable) is correctly set up and secured,
and if it is located in a dry place.
• To avoid pressure losses and ignition problems, use only the correct gas
connection sets. Observe regulations in force in the country of installation.
• Length of the gas hose may not exceed 1.5 m.
• Use only gas hose with, at least, diameters equalling the diameter of the
appliance's gas connection.
• The gas connection stub is found to the right of the control elements. Execute
the connection the following way (Fig. below):
– connect suitable gas hose (a), featuring suitable diameter, to the gas
connection stub (13) of the appliance;
– bind the gas hose (a) and the gas connection stub (13), using a wire (c).
Fig. 2
Summary of Contents for 1505393