- 49 -
Cleaning of the UV lamp
1. Pull the power plug from the socket.
2.
Open the device’s cover (fig. 11).
3. Unscrew the upper side fastening bolts
of the front plate of the device using the
supplied wrench and remove them;
loosen lower side bolts (fig. 13).
4. Using a soft cloth carefully wipe the
dust from the lamp’s fluorescent tube
which might have gathered during the
use of the device.
Fig. 12
5. If possible do not touch the fluorescent tube with bare hands.
6. After cleaning of the UV lamp, retighten the front plate with screws.
Replacement of the UV lamp
1. Pull the power plug from the socket.
2.
Open the device’s cover (fig. 11).
3. Unscrew the upper side fastening bolts of the front plate of the device using the
supplied wrench and remove them; loosen lower side bolts (fig. 13).
4. Dismantle the fluorescent tube by turning it 90° and carefully removing it. Handle
the fluorescent tube with care and if possible do not touch it with bare hands not to
soil the surface during the installation.
5. Finally, retighten the front plate of the device with screws.
6. Close the lid of the device.
NOTE!
In order to ensure the proper operation, the UV lamp (fluorescent tube) should
be always replaced after 8000 hours of work.
Storing of the device
o
If the device is not used for a longer time, clean it thoroughly according to the
instructions above and store it in a dry, clean place, protected from cold, sunlight,
and children. Do not place any heavy objects on the device.