Cleaning
32 / 36
610837
EN
AUTOMATIC SAFETY MECHANISM
High Temperature Protection
If the temperature in the microwave rises to 300°C, the appliance automatically
switches to self-protection mode.
'E01'
is displayed in the digital display and an
acoustic signal sounds.
1. To switch the appliance again to standard operating mode, press the Stop /
Reset
button.
2. Open the appliance door to cool thermal processing chamber.
Low Temperature Protection
When the appliance switches to low temperature state, an acoustic signal sounds,
and
'E02'
is shown in the digital display.
1. Press the Stop / Reset
button to revert the appliance to standard condition.
Protection Against Sensor Failure
In the case of a short circuit, the appliance switches into the self-protection mode,
and 'E03' is displayed in the digital display. Acoustic signals sound.
1. Press the Stop / Reset
button to revert the appliance to standard condition.
The appliance is equipped with a cooling installation. Following an operation cycle
longer than 2 minutes, the fan operates automatically for approx. 3 minutes to cool
the appliance thermal processing chamber down.
Contact the service company, to have the faulty sensor checked and, if needed,
replaced.
6
Cleaning
6.1
Safety Instructions for Cleaning
• Before cleaning, disconnect the appliance from the power supply.
• Leave the appliance to cool down completely.
• Make sure water does not enter the appliance. Do not immerse the appliance in
water or other liquids during cleaning. Do not clean the appliance with a
pressurized water jet.
• Do not use any sharp or pointed, nor metal implements (knife, fork, etc.). Sharp
or pointed implements may damage the appliance, and when in contact with live
parts, they may cause electric shock.
• For cleaning, do not use any scouring agents that contain solvents nor corrosive
cleaning agents. They may damage the surface.
Summary of Contents for 14250M-HLGR