background image

 

 

 

- 32 - 

  Before the first use, remove the protection foil from the device. Remove it slowly to 

ensure no glue resideues remain. Remove possible glue residues with appropriate 
solvent. 

 CAUTION! 

Never remove the rating plate and any warning signs from the device. 

 

  Place the device so that the plug is easily accessible so as to quickly disconneet the 

device if the need arises. 

 
 

Connection 

 DANGER! Risk of electric shock! 

The device can cause injuries due to improper installation!  
Before installation and connecting the local power grid 
specification should be compared with that of the device 
(see rating plate). Connect the device only in case of 
compliance! 
 
Connect the device only to properly installed single 
socket with protective terminal. 
 

 

  If the device was transported in vertical position, wait 2 hours before connecting 

the device to the power supply (embedded condenser). 

  After a power failure or if the plug is removed, the device should not be 

connected to the power supply for at least 5 minutes.

 

  The electrical circuit in the socket must be secured to at least 16A. Only connect the 

device directly to the wall socket; do not use any extension cords or power strips.

 

 

Summary of Contents for 1400T1S2

Page 1: ...1400T1S2 110900 Original Gebrauchsanleitung V1 0916 ...

Page 2: ...7 3 Transport packaging and storage 28 3 1 Delivery check 28 3 2 Packaging 28 3 3 Storage 28 4 Technical data 29 4 1 Overview of parts 29 4 2 Technical specification 30 5 Installation and operation 31 5 1 Installation 31 5 2 Operation 33 6 Cleaning and maintenance 37 7 Possible Malfunctions 39 8 Waste disposal 40 Bartscher GmbH Franz Kleine Str 28 D 33154 Salzkotten phone 49 0 5258 971 0 Germany f...

Page 3: ...g maintenance or cleaning Please keep these instructions and give them to future owners of the device 1 Safety This device is designed in accordance with the presently applicable technological standards However the device can pose a danger if handled improperly and inappropriately All persons using the device must follow the recommendations and instructions in this manual 1 1 Key to symbols In thi...

Page 4: ...sons are under the care of a person responsible for their safety or have received instructions regarding appropriate use of the device Children should be observed to ensure that they are not playing with the device Do not move or tilt the device when in operation Only use the device indoors This device may only be operated in technically proper and safe condition Prevent access of children to the ...

Page 5: ...wer cable should not hang over the side of the working surface Ensure that no one can step on or trip over the cable The power cable must not be folded bent or tangled and must always remain fully unrolled Never place the device or other objects on the power cable Do not lay the power cable over carpets or other inflammable materials Do not cover the cable Keep away the cable from operating range ...

Page 6: ... in case of anomalies during operation before cleaning HOT SURFACE Burn hazard To avoid the hazard results please follow the safety instructions below During normal use the condenser and compressor surfaces may be hot To avoid burning your palm or hands do not touch them with your bare hands Wear protective gloves WARNING Fire or explosion hazard To avoid the hazard results please follow the safet...

Page 7: ...ation and maintenance must be performed by the qualified service personnel only The refrigerated counter as substructure is designed only for cooling preparation and sale of salads fruits vegetables and cold food The refrigerated counter as substructure should not be used for storing of the flammable or explosive materials or fluids like ether alcohol kerosene or glues storing of pharmaceutical pr...

Page 8: ...d by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of developing and improving the useful properties 2 2 Copyright protection The instruction manual including any texts drawings images or other illustrations is copyright No part of this publication may ...

Page 9: ...r The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon completeness In case any part is missing please contact our customer service center immediately 3 3 Storage Keep the pac...

Page 10: ...2 Overview of parts Control elements 1 Housing 2 Ventilation holes 3 Feet 4 4 Control elements 5 Door 6 Grid 1 1 GN 1 7 Drawers 2 8 Digital temperature controller 9 ON OFF switch with integrated lamp green 7 7 2 3 6 9 4 5 8 1 ...

Page 11: ...ooled internal dimensions W 388 x D 540 x H 454 mm 3 shelves with adjustable height right door cooling with circulating air electronic control evaporation of condensed water thermostat ON OFF switch digital display freon free Capacity 120 litres Power supply 0 507 kW 230 V 50 Hz Temperature range 0 C 10 C Cooling medium R134a Dimensions W 1400 x D 682 x H 625 660 mm Weight 86 0 kg Includes 1 grid ...

Page 12: ...aring capacity for the weight of the device including the entire contents Never place the device on flammable surfaces Do not place the device in the vicinity of an open flame electric ovens heating stoves or other heat sources such as direct sunlight High temperatures may adversely affect cooling performance and power consumption Place the device in such a way as to ensure proper circulation of a...

Page 13: ...tallation and connecting the local power grid specification should be compared with that of the device see rating plate Connect the device only in case of compliance Connect the device only to properly installed single socket with protective terminal If the device was transported in vertical position wait 2 hours before connecting the device to the power supply embedded condenser After a power fai...

Page 14: ...he temperature controller Green lamp will come on The digital display shows current temperature in the device The device should reach the required temperature before filling with food products Digital temperature controller Basic settings of the temperature are pre set and reflect the operating temperature in the range of 0 C 10 C inside of the device Dur ing normal operation of the device the dig...

Page 15: ...amming mode press both buttons and hold for 3 seconds LED or flashes and you can start programming Return to a previous indication press both buttons to leave the programming mode and return to a previous displayed value temperature inside of the device LED indicators LED indicators on the digital display indicate the active function LED Display Meaning illuminates compressor active flashes delaye...

Page 16: ...conds for the automatic storing of set value NOTE If you need other settings or parameters please download the attached description of the temperature adjustment or leave this task to customer service employees Turning the device off When the device is not used anymore turn it off with ON OFF switch and disconnect from the power supply pull the plug Defrosting Automatic defrosting The device is au...

Page 17: ... avoid tilting of the device Do not put any warm food or liquids in the device first cool the to the room temperature Stored food products must be always covered or packed While placing food products in the refrigerated counter keep in mind that sufficient space must be maintained between the internal walls of the device and stored food to assure free circulation of air in the device The more item...

Page 18: ...be cleaned regularly o Before cleaning remove the food products from the device and put them in the refrigerator to avoid decay Equipment o Remove grid and GN containers and wash the thoroughly in warm water with neutral cleaning agent Thoroughly rinse in clean water and dry Refrigerated counter o Wash interior of refrigerated counter with food grade disinfectant and soft cloth Wipe washed surface...

Page 19: ...ser gently moving the vacuum cleaner suction nozzle or brush along the condenser ribs o After cleaning replace the protective grid HOT SURFACE Burn hazard The condenser and compressor surfaces may become hot during normal operation Do not touch them with bare hands to avoid burns Use protective gloves When the device will not be used for a longer time o Disconnect the device from the socket pull t...

Page 20: ...cient cooling efficiency Incorrect temperature setting The device is in defrosting phase There is heat source or direct sunlight in the device vicinity Poor air circulation in the device Stored food products are too hot The device is overfilled Correct the temperature setting Wait until the device finishes defrosting check cooling efficiency Assure sufficient distances to the heat sources Assure s...

Page 21: ...posal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove mains connection cable from the device CAUTION For the disposal of the device please consider and act according to the national and local rules and regulations Bartscher GmbH Franz Kleine Str 28 331...

Reviews: