Possible Malfunctions
110644
31 / 32
EN
Boiler filling time-out
The boiler was not filled. The rinse program does not start. Check
whether the water supply valve is open. Switch the appliance off
and on again, and start a new program.
Insufficient water volume for the rinse program
The rinse program was carried out with too little water. Check the
rinse nozzles and clean if necessary. Unit operation is not
interrupted.
Resetting the wash-tank temperature fault
The boiler has not been reheated to operating temperature during
the washing process or during the specified time. Switch the
appliance off and start a new program.
Electromechanical safety
The boiler safety thermostat or tank safety pressure switch has
tripped.
Filling level safety
The water level in the wash-tank is not correct.
Sieve contaminated
The water level in the wash-tank is not correct. The sieve is dirty or
the overflow is incorrectly inserted.
ATTENTION!
The messages are reset when the appliance is switched on and off. If the
actions described above are preformed and, nevertheless, the problem still
persists, contact the authorised service.
Summary of Contents for 110644
Page 1: ...RK401 LPWR 110644...
Page 3: ...Beschr eibung...
Page 4: ...EN 4...
Page 14: ...Technical Data 10 32 110644 EN 4 3 List of Components of the Appliance Fig 12...