10/20/20 

Placement and Mounting 

 

Mount the WeatherBoss in an easily accessible location. Protect the WeatherBoss from 

direct sunlight for better reliability and readability. Moisture can cause corrosion and 
premature failure, so avoid direct water and have all wires enter and leave through liquid-tight 
connectors, waterproof conduit, or seal the wires with silicone sealant. 
  

WARNING: 

Some sealants release acetic acid while curing. Be sure sealant is completely cured 

(up to 3 days) before closing control box to avoid corrosion damage. 
 
To mount the WeatherBoss, remove the front cover and unplug ribbon cable from the relay 
board. Insert the 4 self-drilling screws provided with the WeatherBoss through the 4 screw-hole 
knockouts and fasten the box to the wall. Cover the screw heads with plastic cups provided. 
After all wiring is complete and any sealant cured, reattach the ribbon cable and screw on the 
front cover.  
 
Alternately, the WeatherBoss may be mounted with drywall screws placed through the corner 
holes of the box. 

 

 

 

 

 

 

 

 

 

 

 

 

Rain Sensor 

The rain sensor detects moisture on the surface of the sensor. It does not measure the 

amount of moisture that has fallen. The WeatherBoss junction box has one rain sensor input 
labeled RS. To ensure proper readings, the rain sensor should be mounted in a location that will 
not be sheltered from rain from any direction. The sensor should be mounted in an easily 
accessible location in order to clean any debris from the sensor surface.  
 

PCB 

SCREWHOLE 
KNOCKOUTS 

Weather Alarm 

WR 

TOP 

Summary of Contents for WeatherBoss

Page 1: ...10 20 20 1 WeatherBoss Installation Manual BARTLETT Instrument Co 1032 Ave H Fort Madison IA 52627 319 372 8366 www bartinst com...

Page 2: ...odule it can share alarms and readings with other controllers as well as our Headgrower cloud platform This manual will guide you through placement and use of the sensors The Operation manual will gui...

Page 3: ...igned to be reliable but as with all equipment failures do occur Therefore in situations where loss could result from the failure of the WeatherBoss separate backup thermostat or alarm systems should...

Page 4: ...rews provided with the WeatherBoss through the 4 screw hole knockouts and fasten the box to the wall Cover the screw heads with plastic cups provided After all wiring is complete and any sealant cured...

Page 5: ...als labeled TH There is no special orientation to the thermistor leads This in an informational only sensor and cannot be used to control greenhouse equipment Humidity Sensor The optional humidity sen...

Page 6: ...29 RAIN SENSOR 6 18 30 RAIN SENSOR 7 19 RAIN ALARM 31 Wind Direction 8 20 32 Wind Direction 9 21 WIND OR RAIN ALARM 33 HUM IN 10 22 WIND OR RAIN ALARM 34 HUM POWER 11 23 35 HUM GROUND 12 24 THERMISTOR...

Page 7: ...MINAL DESCRIPTION Pink Wind Speed Connection Orange Wind Speed Connection Red Green Light PAR Sensor Connection Red Yellow Light PAR Sensor Connection PINK ORANGE Communications To Relay Board Red Gre...

Page 8: ...10 20 20 8...

Page 9: ...10 20 20 9...