background image

BAR  H

Elektronik GmbH

®

4/8
9021-0003-A
23.10.2015
A

Page:
Document:
Date:
Revision:

Mini-PLC
STG-115
Art. No. 0850-0115

MANUAL

© 2014-2015 BARTH Elektronik GmbH | Im Depot 1-3 | D-49838 Lengerich | www.barth-elektronik.de
® BARTH is a registered trademark. All rights reserved.

9021-0003-A

5.3.2  Connecting the inputs

You can connect sensors, switches or buttons to the inputs. 
The sensors may be temperature, flow, pressure, photo-
electric sensors or proximity switches, for example.
The STG-115 is well suitable for any sensor featuring a vol-
tage or current loop output, 0 to 10 VDC or 4 to 20 mA, for 
example.

Common features of the inputs IN1-IN10 (X6, X7)

•  IN1 to IN8 are selectable analog/digital inputs
•  IN9 and IN10 are switchable inputs 0-10VDC or 4-20mA
•  Wide input voltage range 0 to 32VDC
•  Comprehensive integrated protection circuits
•  Outstanding electromagnetic compatibility (EMC)
•  Electrostatic discharge protection (ESD)

Due to the pull-down resistors integrated in the STG-115, 
any switch (NO/NC) can simply be connected between the 
positive supply (+VDD) of the STG-115 and the desired input. 

The voltage at any input must not exceed 
32VDC referred to ground (GND).
Higher voltages or reverse voltage lower 
than -32VDC may cause irreversible 
damage of the Mini-PLC!
At both IN9 and IN10 the applied signal 
must not exceed 12VDC or 25mA!

The 8-pole X6 connector named ‚IN1‘ to ‚IN8‘ contains all 
common 0-30VDC inputs of the Mini-PLC. 
The 2-pole X7 connector contains two special inputs named 
‚IN9‘ and ‚IN10‘ which are DIP-switchable from 0-10VDC to 
4-20mA. The default value of both inputs is 4-20mA.
To change the input IN9 from 4-20mA to 0-10V please set 
the switch 1 of the S1 DIP switch from ON to OFF.
To change the input IN10 from 4-20mA to 0-10V please set 
the switch 2 of the S1 DIP switch from ON to OFF.
Switches 3 and 4 of S1 are not related to any function.

Using the inputs IN9 and IN10 as current loop 4-20mA type 
a pull-down resistor of 470 Ohm is used within the STG-115 
to receive a voltage from a current signal.

Using the miCon-L software suite you have to know wether 
or not the inputs IN9 and IN10 are configured as current 
loop type to recalculate the current from the received vol-
tage value within miCon-L. 

5.2 

Wiring

5.3 

Overview

Connectors

X1: 

Power supply (fused)

X2: 

USB connection (PC interface for miCon-L)

X4: 

Common output ports OUT1-OUT8

X5: 

Relay output OUT9

X6: 

Common input ports IN1-IN8

X7: 

Special input ports IN9-IN10 (0-10V/4-20mA)

X8: 

Common ground (bridged parallel)

S1: 

DIP switch to configure X7 ports IN9 and IN10

5.3.1  Connecting the power supply

The STG-115 features an outstanding wide supply voltage 
range from 16 to 32 VDC at lowest current consumption.
So the Mini-PLC can be integrated within battery sup-
plied 24V DC systems (cars, trucks, battery powered cars, 
forklifts and digger, for example).

Turn off the power supply before perfor-
ming any wiring operations!

False electrical connection, voltage 
reversal or disregarding the electrical 
specifications may cause irreversible 
damage of the Mini-PLC!

Connect the supply voltage of 16 to 32 VDC to the X1 termi-
nal named ‚+VDD‘ and ‚GND‘ of the STG-115.
Wire the positive supply to the ‚+VDD‘ marked terminal. The 
negative (ground) will be wired to the ‚GND‘ terminal.
All connectors are carried out as plugable spring terminal 
connectors for a wire gauge of 0.25 to 1.5mm². 

Ensure correct power supply voltage 
range and polarisation! External fusing of 
8A max. is mandatory! 
Disregard may cause irreversible damage 
of the Mini-PLC!

Summary of Contents for Mini-PLC STG-115

Page 1: ...n 2 4 4 Programming with miCon L 3 4 5 Delivery content 3 5 INSTALLATION 3 5 1 Mounting 3 5 2 Wiring 4 5 3 Overview 4 5 3 1 Connecting the power supply 4 5 3 2 Connecting the inputs 4 5 3 3 Connecting...

Page 2: ...he strict accordance of this manual is important since the installation methods peripheral connections usage and maintenance can not be con trolled by BARTH Elektronik GmbH Therefore BARTH Elektronik...

Page 3: ...lease read the BARTH miCon L manual and the BARTH Application Notes on www barth elektronik de 4 5 Delivery content BARTH Mini PLC STG 115 Spring terminal connectors for supply input output 5 INSTALLA...

Page 4: ...ch 1 of the S1 DIP switch from ON to OFF To change the input IN10 from 4 20mA to 0 10V please set the switch 2 of the S1 DIP switch from ON to OFF Switches 3 and 4 of S1 are not related to any functio...

Page 5: ...NO NC switch A logical HIGH within miConL will switch the Mini PLS s supply voltage at OUT1 to OUT8 while the isolated contact of OUT9 changes over NC NO NO NC Aviod a current exceeding 1A 30VDC at OU...

Page 6: ...ged housing with plugable spring terminal connectors Programming miCon L Software graphical function block style simulation programming and visualisation free license model Interfaces USB reserved for...

Page 7: ...charge ESD on IN1 to IN10 20 kV air discharge 30 kV contact discharge IEC EN 61 000 4 2 level 3 Electrostatic discharge ESD on OUT1 to OUT9 8 kV human body model MIL STD883D Electromagnetic fields Fie...

Page 8: ...e event of any alternation which has not been approved by us being made to any device as designated below this statement shall thereby be made invalid Description Mini PLC Type STG 115 Art No 0850 011...

Reviews: