Rev. 1.0 (04.2020)
Jumpers:
JP1
–
Jumper for pump frequency setting
JP2
–
Jumper for pump amplitude setting
JP3
–
Jumper for power supply setting
Others:
POT1
–
Variable resistor for amplitude adjustment
C1
–
is not used with mp6-XOEM
Operation.
To operate a pump with the evaluation board, the following steps are necessary:
Step 1:
Connect the micropump of the mp6-series to the board. Due to the orientation of the connector, the
pump needs to be inserted with its metallic contacts upwards.
Step 2:
Choose the pump frequency setting with Jumper 1
Step 3:
Choose the pump amplitude setting with Jumper 2
Step 4:
Choose the power supply setting with Jumper 3 (CON 1- or USB-port).
Step 5:
Connect the board to the power supply
Pump frequency setting with jumper JP1.
Frequency defined by
clock signal at Pin 3 (CLK)
of screw terminal CON1
This setting has no
functionality with mp6-XOEM
Internal frequency of the mp6-XOEM
(200 Hz)
More information on the frequency setting with the CLK signal can be found in the mp6-XOEM manual.