Installation Instruction
Xbeam LTE EX Antenna
BARTEC
TECHNOR AS
Vestre Svanholmen 24
4313 SANDNES
NORWAY
Tel.: +47 51 844100
Fax: +47 51 844101
[email protected]
www.bartec-technor.no
Reservation
Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
EN 2/4
24
05
2-
5
v1
In
st
al
la
tio
n
In
st
ru
ct
io
ns
X
b
ea
m
L
T
E
E
X
Safety Instructions
The technical data, which are on the marking
label need to be maintained just like all possible
warning (caution) texts on the outside of the
product.
On the basis of the Category or EPL marking
you’ll have to verify that the product is installed
in the correct zone.
Zone Category
EPL
Suitability
0
1G only
Ga only
1
2G
Gb
2
3G or 2G Gc or Gb
20
1D only
Da only
21
2D
Db
22
3D or 2D Dc or Db
This table gives only information about main
Equipment Protection Level which is applicable
for the product. The marking label is leading.
The table shows in which zone this product may
be installed under application of the belonging
EU-Type Examination Certificate or IECEx
Certificate of Conformity.
Rebuilds and changes to the product are not
permitted.
Use explosion proof products in good shape
only, which means; undamaged, healthy
maintenance condition.
Take care of all national applicable safety & work
instructions and all safety instructions
mentioned in this manual whenever work is
necessary to Ex products.
For installation requirements we redirect you to:
EN 60079-14: 2014 or IEC 60079-14: 2013.
Marking
Particularly important points in these instructions
are marked with a symbol:
DANGER indicates a hazardous situation which,
if not avoided, will result in death or serious
injury.
WARNING indicates a hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION indicates a hazardous situation
which, if not avoided, could result in minor or
moderate injury.
NOTICE is used to address practices not
related to personal injury.
Note
Important instructions and information on
effective, economical and environmentally
compatible handling.
Conformity to standards
The explosion proof control panels have been
examined according following standards
(depending on technical execution and
application more than one standard may be
applicable).
Main standards
EN 60079-0:2018 / IEC 60079-0:2017 Ed 7.0
EN IEC 60079-7:2015+A1:2018 /
IEC 60079-7:2017 Ed 5.1
EN 60079-31:2014 / IEC 60079-31:2013 Ed 2.0
EN 60529:1991/A1:2000/A2:2013/AC:2016-12
EN 50581:2012, EN 50419:2006
Technical data
Page 1 of these installation instructions
describes the exact technical execution. Below
follows an overview of possible variants and the
general technical data.
Marking according EN-IEC 60079-0
The marking on page 1 is leading.
Type(s) of Protection against ignition
Ex eb mb IIC, IIB, IIA T6 Gb
Ed tb IIIC T85°C Db, IP66 / IP67
Gas group
This product is certified for gas: IIC, IIB, IIA.
Dust group
This product is certified for dust: IIIC.
Temperature class or maximum surface
temperature
The temperature class for this product is: T6.
Equipment Protection Level
The EPL for this product is: Gb and Db.
Ingress Protection degree
The product has an IP66 / IP67 rating according
to EN / IEC 60529.
Ambient temperature range
-40°C to +60°C.
Maximum ambient temperature range
-40°C to +60°C.
Note
For deviating ambient conditions, please consult
BARTEC.