Technical data
Subject to technical changes.
10/2020
11/40
4
Technical data
4.1
Explosion protection
ATEX Zone 2 / Zone 22
Type
B7-A2M3-****/****
MC93
ex
-NI
Labelling
Ex II 3G Ex ic op is IIC T6 Gc
Ex II 3D Ex ic op is IIIB T80°C Dc IP 65
-20 °C ≤ Ta ≤ +50 °C
Test certificate
EPS 19 ATEX 1 239 X
Standards
See chapter: EU Declaration of Conformity
IECEx Zone 2 / Zone 22
Type
B7-A2M3-****/****
MC93
ex
-NI
Labelling
Ex ic op is IIC T6 Gc
Ex ic op is IIIB T80°C Dc IP 65
-20 °C ≤ Ta ≤ +50 °C
Test certificate
IECEx EPS 19.0108X
Standards
See chapter: EU Declaration of Conformity
Class I, II, III, Division 2
Type
B7-A2M2-****/****
MC93
ex
-NI
Labelling
Class I, Div. 2, Groups A, B, C, D;
Class II, Div. 2, Groups F, G;
Class III; T6
Test certificate USA and Canada UL E321557
Standards
UL 121201 and
CSA C22.2 NO. 213
X - labelling (special conditions of use for secure operation within the potentially
explosive atmosphere)
The ambient temperature range is -20 °C ≤ Ta ≤ +50 °C.*
The device must be protected from impact with high impact energy, from intense UV-
irradiation, and strongly charge generating processes.
It is not allowed to use connectors inside the potentially explosive atmosphere.*
It is not allowed to remove, change and/or charge the battery inside the potentially
explosive atmosphere.*
The battery must be locked within the potentially explosive atmosphere.*
*See individual chapters on the items in this Quick Start Guide.