1. Control Panel Maintenance
WARNING:
REMOVE THE IGNITION KEY BEFORE WORKING IN ENGINE COMPARTMENT.
TURN BATTERY ISOLATION SWITCHES OFF.
•
To replace an illumination bulb:
Release the panel from its mounting. The bulbs
are accessible from the rear of the panel. Remove the wires, unscrew the nut and pull
out the bulb housing from the panel. Remove the bulb and replace. Refit bulb housing,
screw the nut back up and refit the wires.
•
To replace any gauge:
Release the panel from its mounting. The gauges are
accessible from the rear of the panel. Unplug the wire connectors, unscrew and pull
the gauge out of the panel. Replace the gauge and refit. Reattach the wiring
connectors.
Periodically squirt a lubricant into the key switch slot when the key has been
removed. A lubricant such as WD40
– with silicon, would be suitable. Other lubricants
are available. Then with the battery master switch turned off, operate the key switch
a couple of times. This will ensure the lubricant works into the mechanism.