INSTALLATION INSTRUCTIONS
800.533.3948 • www.barronltg.com
2
E110
Wiring
Make electrical connections as follows:
Note:
This fixture auto adjusts for voltages from 120-277V.
Cap all unused leads to prevent shorting.
EM MODELS:
Securely connect the battery before closing the unit.
To prevent battery damage connect battery only after continuous
AC power can be supplied to the unit.
IMPORTANT:
Weather-proof your outdoor installation, be sure to
seal all holes in the fixture’s housing such as the mounting,
conduit, plugs, sensors, photocontrols, etc. with silicone sealant.
Troubleshooting
If the E110 does not turn on:
1. Check incoming voltage to the LED driver, voltage must be between 120VAC and 277VAC.
2. If all LEDs do not illuminate, the driver(s) may be disconnected. Ensure driver(s) are secure. If secure, use
multimeter to check voltage is present at the output of the power supply. If low or no voltage, consult factory.
3. If some, but not all LEDs are illuminated, consult factory for additional technical support. Please have the catalog
number and photos available when contacting technical support.
EM MODELS:
Check that the battery and test button are securely connected. Check using a multimeter if the
voltage is below the rating written on the battery, battery may need to be replaced.
Black - Line
White - Neutral
Green/Yellow Green - Ground
If Dimming is used:
Purple - DIM+
Gray - DIM-
20070136 REV 2 - 02/19