77
BARRETT PRC-4090 TACTICAL HF SDR TRANSCEIVER - ADVANCED OPERATION
Audio - Advanced
From the
Settings
menu, select
Audio
.
For information on Beep Level, Alarm
Audio Level and Ring tones, see Basic
Rx
Configuration
This option sets whether the transceiver
receives audio via the antenna or from
the Line.
Selecting “Internal Audio” ensures the
transceiver receives audio through the
antenna.
For “External Audio”, the transceiver
receives through the auxiliary socket’s
600 ohm balanced audio port. This
can be used in many situations eg for a
remote receiver in split site operations
and audio is received from the remote
site.
Tx
Configuration
This option sets whether the PRC-4090
transmits to the antenna or down the
line.
Audio Bandwidth
This section allows the audio bandwidth to be tailored to an operator’s
requirements.
Select either:
300 Hz - 2700 Hz: used for reduced bandwidth voice operation
300 Hz - 3000 Hz: standard voice and data operation
300 Hz - 3200 Hz: recommended for use with clover waveforms
300 Hz - 3400 Hz: recommended for use with digital voice and Stanag wave
forms
Settings
Audio
When set as “local” the transceiver transmits through the antenna.
When set as “remote”, the transmit audio is sent through the auxiliary socket’s
600 ohm balanced audio port.