Power connecting procedure: 

 

STEP 1  

Take out 4 pin terminal block located in the included mounting kit package. 

STEP 2  

Connect power wires to +V1- or +V2- with corresponding polarity. Connect the grounding 
wire to the ground screw. 

STEP 3  

Plug into terminal block socket shown above. Polarity needs to match V+ and V-. 

 
WARNING 

Always SHUT OFF power source to connect power wire. 

WARNING 

Always ground the power source to maintain a clean power input. Cheaply made power 
supplies create too much noise and will cause the power input to fluctuate when connect 
to this unit. To avoid this, always ground the power source to maintain a clean power 
input. 

 
 
 

 

 

Summary of Contents for PC-IA100 Series

Page 1: ...User Manual PC IA500 Industrial Switch Version 5 2019 ...

Page 2: ...l mounted Din rail brackets and wall mounted brackets are included Power connection This unit comes with a 4 pin terminal block It can be operated from 12 56VDC power source Always make sure your input voltage is within this supported voltage range for each model WARNING Any exceeded input voltage will not make this unit function and may damage this unit To connect power This unit supports two pow...

Page 3: ...round screw STEP 3 Plug into terminal block socket shown above Polarity needs to match V and V WARNING Always SHUT OFF power source to connect power wire WARNING Always ground the power source to maintain a clean power input Cheaply made power supplies create too much noise and will cause the power input to fluctuate when connect to this unit To avoid this always ground the power source to maintai...

Page 4: ...Page 4 7 LED indicator ...

Page 5: ... TX RJ 45 port LNK Link Active Green ON TX port is detected Flashing TX data is transmitting receiving Reserve polarity protection Present Overload current protection Present Power Supply Redundant Dual DC 12V 56V Power Input Power Consumption 2 24W 48 VDC full load Removable Terminal Block Provide 1 power 2 Pin Wire range 0 34mm 2 to 2 5mm 2 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 2...

Page 6: ...s Safety LVD EN60950 1 EMC CE FCC EN 55032 24 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 6KV Air 8KV IEC 61000 4 4 EFT Power 2KV Signal 2KV IEC 61000 4 5 Surge Power 2KV Signal 2KV Vibration EN 60068 2 6 ...

Page 7: ...Page 7 7 Housing Dimension mm ...

Reviews: