Hardware Installation 

Installation Steps 

This  section  will  explain  how  to  install  LT-802GBTMEseries:  10-port  industrial  gigabit  managed 
Ethernet switch, with 8*10/100/1000Tx Gigabit Ethernet and 2*100/1000 SFP Slots

 

 

Installation Steps

 

Step 1. 

Unpack the industrial Ethernet switch from the original packing box.

 

Step 2. 

Check if the DIN-Rail bracket is screwed on the industrial Ethernet switch.

 

 

If  the  DIN-Rail  is  not  screwed  on  the  industrial  Ethernet  switch,  please  refer  to  the 

DIN-Rail 

Mounting

 section for DIN-Rail installation.

 

 

If  you  want  to  wall  mount  the  industrial  Ethernet  switch,  please  refer  to  the 

Wall  Mounting

 

section for wall mounting installation.

 

Step 3. 

To  hang  the  industrial  Ethernet  switch  on  a  DIN-Rail  or  wall,  please  refer  to  the 

Mounting 

Installation

 section.

 

Step 4. 

Power on the industrial Ethernet switch and then the power LED light will turn on.

 

 

If you need help on how to wire power, please refer to the 

Wiring the Power Inputs

 section.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 5. 

Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection.

 

Step 6. 

Insert one side of the RJ-45 cable into switch’s Ethernet port and on the other side into the 

networking  device’s  Ethernet port,  e.g. switch  PC or  server.  The Ethernet port’s  (RJ-45)  LED 

on the industrial Ethernet switch will turn on when the cable is connected to the networking 

device.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 7. 

When all connections are set and the LED lights all show normal, the installation is complete.

 

Summary of Contents for LT-802GBTME

Page 1: ...barox Kommunikation LT 802GBTME User Manual Version 1 0...

Page 2: ...mited to the implied warranties of merchantability and fitness for a particular purpose Barox Kommunikation may make improvements and or changes to the product and or specifications of the product des...

Page 3: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna I...

Page 4: ...re Description 4 Physical Dimensions 4 Front Panel 5 Top View 5 LED Indicators 6 Ethernet Ports 7 Cabling 8 Wiring the Power Inputs 11 Wiring the Fault Alarm Contact 12 Mounting Installation 13 DIN Ra...

Page 5: ...s is designed to meet any needs for industrial automation outdoor application and harsh environments Software Features Network Redundancy STP RSTP MSTP ITU T G 8032 Ethernet Ring Protection Switch ERP...

Page 6: ...dded 8 10 100 1000Tx Gigabit Ethernet and 2 100 1000 SFP Slots Store and forward switching architecture 8K MAC Address Table Supports 9 6Kbytes Jumbo Frame 2 000VDC Power line EFT protection 6000VDC E...

Page 7: ...ets and screws 1 RJ45 to DB9 Serial Console cable 1 DC cable 18 AWG DC jack 5 5x2 1mm Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on...

Page 8: ...Figure 2 1 below shows the physical dimensions of LT 802GBTMEseries 10 port industrial gigabit managed Ethernet switch with 8 10 100 1000Tx Gigabit Ethernet and 2 100 1000 SFP Slots W x H x D is 54mm...

Page 9: ...t switch is shown below in Figure 2 2 Figure 2 2 The Front Panel of LT 802GBTMESeries Top View Figure 2 3 below shows the top panel of the LT 802GBTMEseries switch that is equipped with one 6 pin remo...

Page 10: ...te Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active and works well Flashing Ring works abnormally or misconfigure Off Ring Ne...

Page 11: ...wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operation Users can use straight through cables see Figure 2 4 for all network connections to...

Page 12: ...er Cable Schematic Cabling Use the four twisted pair category 5e or the above cabling for RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be le...

Page 13: ...below in Figure 2 9 Notice that the triangle mark is at the bottom of the SFP slot Figure 2 10 shows SFP transceiver module was inserted Figure 2 9 Transceiver to the SFP Module Figure 2 10 Transceive...

Page 14: ...ep 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 12 Figure 2 12 Remove LC Connector Step 2 Push down the metal clasp and pull th...

Page 15: ...R2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 14 Figure 2 14 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below...

Page 16: ...status including power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Fig...

Page 17: ...ket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch Step 2 To remove...

Page 18: ...nikation 14 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Ethernet switch from the rail do the opposite from the a...

Page 19: ...top and bottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounti...

Page 20: ...he industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you ne...

Page 21: ...To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indic...

Page 22: ...ork VLAN IEEE 802 1ad Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritization IEEE 802 1X Network Authentication Protocol CSMA CD IGMP v1 v2 SNMP v1 v2c v3 TFTP SNTP SMTP RARP RMON...

Page 23: ...Installation DIN Rail mounting and Wall mounting Operating Temperature Standard 10 C 65 C 14 F to 149 F EOT 40 C 75 C 40 F to 167 F Operating Humidity 5 to 95 Non Condensing Storage Temperature 40 C...

Reviews: