Remove the reserve tank.
1
2
ouuoov-023
Change of Coolant_003
1
Reserve tank
2
Reserve tank cap
Open the reserve tank cap, and then drain
the coolant.
Install the reserve tank.
Clean the radiator with clean water to
remove any debris or rust.
Drain all water from the radiator.
Follow the steps below to fill with coolant.
The coolant quantity, including the reserve
tank, is 3.1 dm
3
(3.1 L).
Install the drain plug.
Supply clean water and antifreeze into the
radiator up to the radiator cap opening.
Close the radiator cap.
Supply clean water and antifreeze into the
reserve tank up to the "FULL" mark.
Close the reserve tank cap.
Start the engine, and then idle for several
minutes to bleed air from the system.
Stop the engine, and then allow the radiator
to cool.
Check if the coolant level in the reserve tank
is between "FULL" and "LOW", and then
supply coolant if necessary.
Close the hood.
Change of Hydraulic Oil
Caution
Be careful with hot oil, which could cause
burns if it contacts your skin.
[4]
[5]
4.
5.
6.
7.
[1]
[2]
[3]
[4]
[5]
8.
9.
10.
11.
Important
When you change the hydraulic oil, be sure to
drain it into a bowl and discard it in
accordance with local laws and regulations.
Important
If the hydraulic oil emulsifies or if it becomes
even slightly less transparent, change the oil
immediately.
Important
Use Shell Tellus S2M46 (or equivalent) as
hydraulic oil.
In case of an equivalent, consult
Characteristics of Hydraulic Oil and use
hydraulic oil whose characteristics are
superior to those of the specific hydraulic oil.
Especially regarding kinematic viscosity and
viscosity index, use of hydraulic oil whose
figures are less than those of the specified
hydraulic oil will cause a malfunction in the
hydraulic circuit.
Note:
Characteristics of Hydraulic Oil
Specified Hydraulic Oil
Shell Tellus S2M46
ISO Viscosity Grade
ISO VG46
Density
15 °C (59 °F)
0.873 g/cm
3
(0.0315 lb/in
3
)
API Gravity
30.6
Flash Point (Open Cup)
230 °C (446 °F)
Pour Point
-30 °C (-22 °F)
Kinematic
Viscosity
40 °C (104 °F)
46 mm
2
/s (46 cSt)
100 °C (212 °F)
7 mm
2
/s (7 cSt)
Viscosity Index
109
Follow the steps below to remove the old oil.
Start and run the engine to warm up the
oil.
On a level surface, lower the mower units,
and then stop the engine.
Remove the drain plug of the hydraulic
tank and drain the old oil into a bowl.
1.
[1]
[2]
[3]
LM331
Maintenance
Page 6-12
Adjustment and Replacement
Summary of Contents for LM331
Page 6: ...LM331 Introduction...
Page 8: ...LM331 Contents...
Page 14: ...LM331 Safety Page 1 6 Safe Operating Practices...
Page 36: ...LM331 Product Overview Page 3 20 Operation Decals...
Page 66: ...LM331 Handling Instructions Page 5 22 Transporting...
Page 92: ...LM331 Repair Page 7 8 Towing...
Page 102: ...LM331 Appended Table Page 8 10 List of Adjusted Value...