Barnstead International 379 Series Operation Manual Download Page 13

13

Culture Incubator, Series 379 — Models I37290-26, I37925 & I37924

KEY

PART

DESCRIPTION

KEY

PART

DESCRIPTION

NO.

NO.

NO.

NO.

1

PT374X2

Plate (2 required) 

44

PT379X1

Back Insulation

2

BC374X2

Bracket 

45

JC374X1

Fastener, Nut (2 

3

FNX101

Fastener, Nut (6 required) 

required)

4

BC374X3

Bracket

46

FN374X1

Fastener, Washer

5

FW179X1

Fastener, Washer

(2 required)

6

BC374X4

Bracket (2 required)

47

FWX12

Bracket

7

FW374X1

Fastener, Washer (2 required)

48

BC188X1

Fastener, Screw 

8

CNX98 

Control  

(4 required) 

9

FWX72 Fastener, 

Washer 

 

49

FSX20

Element 

Assembly, 

120V 

10

FSX35 

Fastener, Screw

EL379X1

Element Assembly, 220V 

11

CU374X1

Coupling (2 required)

EL379X2

Element Assembly, 100V

12

FSX27

Set Screw (2 required) 

50

EL379X3

Terminal Block 

13

JN374X1

Door Insulation including

51

TRX77

Fastener, Screw 

5/TA374X1's; 2/GS374X2's; 

52

FSX184

Terminal, for ground

2/GS374X1’s

53

TRX73

Fastener, Screw (2 required) 

14

FSX275

Fastener, Screw (2 required) 

54

FSX115

Fastener, Screw (6 required) 

15

DL379X6

Silk screened Door 

55

FSX93

Fastener, Screw 

16

HNX10

Handle

56

FSX31

Snap Bushing 

17

MEX147

Thermometer 57

JSX61

Shelf 

18

SF374X1

Shaft SH379X1

19

FTX2

Foot (2 required)

20

GMX2

Grommet

21

PL374X1A

Pilot Light, 100, 120V 

Items not shown on the exploded view:

PL379X1A

Pilot Light, 220V

FZX8

Fuse, 100V

22

DL379X7

Dial Plate (Access Cover Silk screened)

58

FZX16

Fuse, 120, 220V

23

FSX184

Fastener, Screw (2 required) 

CA374X1A Capacitor Assembly,

24

KBX27

Knob 

connected to terminal block, 

25

FZX9

Fuse Holder 

100, 120V

26

CR374X1

Cord Set, 100, 120V 

CA333X1A Capacitor Assembly,

CR375X2

Cord Set, 220V

connected to terminal block, 

27

SRX16

Strain Relief 

220V

28

FSX11

Fastener, Screw

FCX4

Fastener Cable Tie (3 

29

Nut Supplied with FZX9

required)

31

FNX101

Fastener, Nut

WM374X2A Wire Assembly (black) 

32

FSX19

Fastener, Screw (4 required) 

100, 120V

33

FTX4

Foot (4 required)

SC379X1A Wire Assembly (black) 220V

34

FWX61

Fastener, Washer (4 required)

WM374X4A Wire Assembly 

35

CS379X2

Case Assembly 

(green/yellow)

36

A

Bottom Insulation 

WM374X3A Wire Assembly (white)

37

JN374X2

Fastener, Washer (2 required)

LT379X2

Operating Instructions/

38

FWX79

Side Insulation (2 required) 

Parts List

39

JN374X4

Top Insulation 

DLX97

Warning Label

40

JN374X3

Plate (2 required)

41

PT374X4

Plate (2 required) 

42

PT374X5

Spring Clamp (2 required) 

43

FCX32

Plate

Replacement Parts List

Summary of Contents for 379 Series

Page 1: ...CULTURE INCUBATOR TYPE 37900 OPERATION MANUAL AND PARTS LIST SERIES 379 Models I37925 I37924 I37920 26 LT379X2 2 4 04 Serial Number__________________...

Page 2: ...eration 7 Calibration Procedures 7 Operational Precautions and Limitations 7 Troubleshooting 8 Maintenance and Servicing 9 Replacing Door Hinge Assembly 9 Removing Door Insulation 9 Replacing Fuse 9 R...

Page 3: ...e inte rior surfaces of this incubator will become hot during use 3 Refer servicing to qualified personnel Please note the following warning THIS WARNING IS PRESENTED FOR COMPLIANCE WITH CALIFORNIA PR...

Page 4: ...intaining the insulating materials or when other wise disturbing the materials in a manner which causes release of dust or fibers therefrom Through the use of proper handling procedures you can work s...

Page 5: ...30 C to 65 C Principles of Operation A bimetallic thermostat energizes a resistant heating ele ment which is in contact with the thermally conductive chamber Turning of the adjustment knob located at...

Page 6: ...against palm of hand or soft pad to disperse any bubbles Keep in vertical position until liquid has expanded into lower part of capillary The following test data is given for your information Test Da...

Page 7: ...Equipment required consists of a water bath controllable within tenths of a degree centigrade and a National Institute for Standards and Technology NIST reference thermometer The supplied thermometer...

Page 8: ...other components Defective cord set Replace cord set Faulty control Replace control Open element Replace element Unstable temperature Loose control Tighten control Faulty control Replace control Temp...

Page 9: ...aded Push in and turn to the left Remove fuse c Install replacement fuse Replacing Control a Remove control knob b Remove two screws from access cover c Remove two black wires from control d Remove co...

Page 10: ...ires and element lead wires b Remove two spring clamps from nylon spacer nuts c Remove plate and insulation d Loosen two screws in rear of inner chamber but do not remove e Remove element f Re assembl...

Page 11: ...el No and BI Part No Number I37924 I37925 C1 Capacitor 002mfd 500V CAX41 CAX41 DS1 Lamp cycle light PLX73 PLX73 F1 Fuse 1 amp 100V 5 amp 120V FZX8 FZX16 HR1 Element 200 ohm 100V 288 ohm 120V EL379X3 E...

Page 12: ...12 EXPLODED VIEW...

Page 13: ...MEX147 Thermometer 57 JSX61 Shelf 18 SF374X1 Shaft SH379X1 19 FTX2 Foot 2 required 20 GMX2 Grommet 21 PL374X1A Pilot Light 100 120V Items not shown on the exploded view PL379X1A Pilot Light 220V FZX8...

Page 14: ...or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your request then contact our Custome...

Page 15: ...l Refrigeration Molding Media P 80 Basic WCI Refrigeration WCI Freezer Flexible Concrete Curing Flexible Type 75 AF FDM Formboard Cold Storage Wall Hullboard Flexible Marine Acoustical Backing Board M...

Page 16: ...of published human and animal studies The human data included large scale mortality studies of U S and European fiberglass wool factory workers IARC concluded that the human studies did not provide su...

Page 17: ...se of the neck and long pants Skin irritation from exposure to fiberglass is known to occur chiefly at pressure points such as around the neck wrist and waist Wear gloves when handling product Work Hy...

Page 18: ...ection 10 Shipping Information DOT Shipping Description NA Not applicable ID Number None IMO Class Number NA Hazard Classification Primary Nonhazardous Label s Required if not excepted NA EPA Hazardou...

Page 19: ...19...

Page 20: ...without further force or effect if there is any i repair made to the product by a party other than BARNSTEAD or its duly authorized service representa tive ii misuse including use inconsistent with wr...

Reviews: