Barnes SE411HT Series Installation Manual Download Page 18

18

CP&S control panel part no. and brand
Number of pumps operated by control panel

NOTE:

 At no time should holes be made in top of control panel, unless proper sealing devices are utilized.

Control panel manufactured by others
Company name
Model number
Short 

circuit 

protection 

      Type

Number and size of short circuit device(s) 

 

 

 

 

Amp rating

Overload 

type 

     Size 

 Amp 

rating

Do protection devices comply with pump and motor Amp rating?
Are all connections tight?
Is the interior of the panel dry?

ELECTRICAL READINGS:
Single Phase:

Voltage supply at panel line connection, Pump Off, L1, L2
Voltage supply at panel line connection, Pump On, L1, L2
Amperage: Load connection, Pump On L1 

 

 

L2

Three Phase:

Voltage supply at panel line connection, Pump Off, L1 - L2 

 

L2 - L3   

 

L3 - L1

Voltage supply at panel line connection, Pump On, L1 - L2 

 

L2 - L3   

 

L3 - L1

Amperage: Load connection,  

       Pump On L1   

 

L2 

 

 

L3

FINAL CHECK:

Is pump seated on discharge properly? 

 

 

 

Check for leaks?

Does check valve(s) operate properly?
Flow: Does station appear to operate at proper rate?   

 

Pump down time

Noise level: 

High 

 

 

Medium   

 

Low

Comments:

Equipment diffi culties during start-up:

MANUALS:

Has operator received pump instructions and parts manual?
Has operator received electrical control panel diagram?
Has operator been briefed on Warranty?
Address of local CP&S Representative/Distributor:
I have received the above information (Name of Operator)
Name of Company
 

 

 

 

 

 

 

 

 

 

 

Date:

I Certify this report to be accurate (Name of Start-Up person)
Employed 

By: 

         Date:

Date and time of Start-Up
Present at Start-Up
(  ) Engineer: 

 

 

 

 

 

(  ) Operator:

(  ) Contactor: 

 

 

 

 

 

(  ) Other:

To be fi lled out by factory:

Start-Up form checked by:   

 

 

 

Date warranty registration mailed:

Manual Index

Summary of Contents for SE411HT Series

Page 1: ...stant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Pi...

Page 2: ...FICATIONS 4 B GENERAL INFORMATION 5 C INSTALLATION INSTRUCTIONS 5 6 D START UP OPERATION 7 E PREVENTATIVE MAINTENANCE 7 F SERVICE AND REPAIR 7 10 G REPLACEMENT PARTS 10 TROUBLE SHOOTING 11 CROSS SECTI...

Page 3: ...DO NOT insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without...

Page 4: ...Stainless Steel PAINT Air Dry Enamel SEAL Design Single Mechanical Reservoir Secondary Exclusion Seal Material Carbon Ceramic Buna N Hardware 300 Series Stainless CORD ENTRY 15 ft 5m Cord with plug On...

Page 5: ...presentative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These...

Page 6: ...d in any way except for shortening to a speci c application Any splice between the pump and the control panel must be made in accordance with the electric codes It is recommended that a junction box i...

Page 7: ...the pump to operate through it s pumping cycle The time needed to empty the system or pump down time should be recorded on the start up sheet SECTION E PREVENTATIVE MAINTENANCE As the motor is oil ll...

Page 8: ...and inspect joints for air bubbles If after ve minutes the pressure is still holding constant and no bubbles are observed slowly bleed the pressure and remove the gauge assembly Replace the pipe plug...

Page 9: ...ghten socket head screws 15 into motor housing Slide the friction rings 9b grommet 9c and gland nut 9a into motor housing and tighten gland nut to 17 5 ft lbs Re ll with cooling oil as per paragraph F...

Page 10: ...A one or two letter suf x may follow this number to designate the design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers a...

Page 11: ...ler for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so th...

Page 12: ...12 FIGURE 10 Manual Index...

Page 13: ...13 FIGURE 11 Manual Index...

Page 14: ...Ft 100502XC 30 Ft 100502XF 50 Ft 9a 1 051448 Gland Nut 1 16 Stainless 9b 2 051449 Friction Ring 9c 1 051451 Grommet 12 1 016660 Self Tapping Screw 8 32 x 3 8 lg Stainless 13 1 019289 O Ring 14 1 0930...

Page 15: ...15 Testing is performed with water speci c gravity of 1 0 68 F 20 C other uids may vary performance SERIES SE411HT Manual Index...

Page 16: ...TING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTOR...

Page 17: ...impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor measured...

Page 18: ...ump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks D...

Page 19: ...STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Systems In...

Page 20: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE Manual Index...

Reviews: