background image

11

PARTS KITS

Seal Repair Kit ...........P/N: 108303  

Item #’s 6,7,12,13,15,20,25,26,35,36,47

Overhaul Kit .............. P/N: 127238 

108303 & Item #’s 9, 18, 28, 29, 31A, 31B, 31C, 31D, 38

Cutter Kit - PGPP .......P/N: 108330 

Item #’s 5, 6, 7, 9, 15, 23, 26

Cutter Kit - PGPH .......P/N: 108330A 

Item #’s 5, 6, 7, 9, 15, 23, 26

PARTS LIST

ITEM

QTY

PART NO.

DESCRITION

1

1

108344
118246

Volute
Volute (CE)

2

1

110331

Handle (AU model)

3

1

108343

Seal Plate

4

1

108342
110328

Motor Housing (STD)
Motor Housing (AU model)

5

1

082085A
082085B

Shredding Ring (OGVF)
Shredding Ring (OGVH)

6

1

067556

Washer

7

1

070704

Skhd Screw, 1/4-20 x .75” SS

8

1

108369 †

Discharge Flange 1-1/4” NPT

9

1

082088

Radial Cutter

10

1

109026B
109026BTD

Impeller, 5.62” Dia. (OGVH)
Impeller, 5.13” Dia. (OGVF)

11

1

625-01558

O-Ring (-223)

12

4

1-131-1 †

Screw, 5/16-18 x 1.25” SS

13

1

067564

Square Ring

15

14

026322

Lockwasher, 5/16” SS

16

A/R

---------

LOCTITE™ RC609

17

A/R

---------

LOCTITE 242

18

2

062941 †

5/16” Flatwasher

20

1

110395SD

Seal, outer Silicon-Carbide (STD)

22

A/R

---------

Permatex Sealent 2C

23

1

016079

Shim set

24

3 Qts.

029034

Cooling Oil - Mtr. Housing

25

1

095368

Square Ring

26

4

1-300-1

Screw, 5/16-18 x 1.25”, SS

ITEM

QTY

PART NO.

DESCRITION

28

1

061143

Retaining Ring

29

1

Q10-36-E4

Ball Bearing, Lower

31

1

108368A

Motor, 2HP, 240 Volt, 1 Phase
w/capacitors & Ground wire
(Supplied with Upper Bearing)

31A

1

115327A-RC Capacitor, Run

31B

1

115327A-SC Capacitor, Start

31C

1

105111B

Ground wire

31D

1

016660

Screw, Self-Tap #8-32 x .31”

31E

6

039462

Cable tie strap

34

1

103760

Terminal Block, Power, Manual

35

1

2-31051-224 O-Ring

36

2

1-156-1

Screw, 5/16-18 x 1.00” SS

37

1

109498XC
109498

12/3 Cord Set, 30 Ft
15Ft Cord on CC, CE,CT

38

1

014270

Pipe Plug, C’sunk, 3/8” NPT

39

3

110660

1/2” x 2-1/2” Nipple

40

3

111328

1/2” x 1”  Reducer

47

1

105197

Retaining Ring

48

1

625-02117

Sleeving

Contact your local Distributor or the Factory for other impeller 
sizes, seal materials, cord lengths and other optional equipment.

(*)   AUE - ESPS Level Control
(**) Items 31A thru 31E are included with item 31 motor.

(†) 

L Series Only. NOT USED ON CC, CE, CT.

Summary of Contents for PGPH Series

Page 1: ...ystems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax...

Page 2: ...NG Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without...

Page 3: ...der pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pres...

Page 4: ...N Hardware 300 series stainless steel CORD ENTRY 30 Ft 9 1m 15 Ft 4 5m Cord on Compact series CC CE CT Custom Molded Quick Connected for sealing and strain relief CORD CSA UL Approved 12 3 12 5 Type S...

Page 5: ...t 10 voltage at motor Recommended Breaker Heater Sizes Pump Model HP Phase Volts Breaker Size All PGP Series Pumps 2 1 240 25 AMP The nameplate is located on top of the pump This contains the pumps pa...

Page 6: ...owline knot where shown per the directions provided Steps 1 through 5 On the CT Not Shown series tie bowline knot on the eyebolt On the L and AUE series tie bowline knot on the lifting handle See Fig...

Page 7: ...n Ontario Canada 905 457 6223 INSTALLATION Location The pump is designed with pipe legs to keep a minimum of 3 inch clearance THIS PUMP MUST BE INSTALLED WITH A MINIMUM OF 3 INCHES CLEARANCE UNDER THE...

Page 8: ...female end of cord plug into housing bore aligning alignment mark with hole in terminal block see Figure 4 Tighten bolts on compression flange until flush with motor housing FIGURE 4 OGV L Single phas...

Page 9: ...freedom of operation 7 Open valve 8 Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verif...

Page 10: ...10 FIGURE 6...

Page 11: ...0395SD Seal outer Silicon Carbide STD 22 A R Permatex Sealent 2C 23 1 016079 Shim set 24 3 Qts 029034 Cooling Oil Mtr Housing 25 1 095368 Square Ring 26 4 1 300 1 Screw 5 16 18 x 1 25 SS ITEM QTY PART...

Page 12: ...Notes...

Page 13: ...XVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SHU...

Page 14: ...t To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by th...

Page 15: ..._ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating _______________...

Page 16: ...FRQWUROV LQVWDOOHG DZD IURP WXUEXOHQFH 6BBB 12BBB V OHYHO FRQWURO RSHUDWLQJ SURSHUO 6BBB 12BBB V SXPS IXOO VXEPHUJHG GXULQJ RSHUDWLRQ 6BBB 12BBB ROORZ XS RUUHFWLYH FWLRQ 5HTXLUHG 6BBB 12BBB GGLWLRQDO...

Reviews: