background image

12

terminal block (21) into the housing so it seats completely 
below the snap ring groove. Place snap ring (19) into groove 
in cord entry bore of housing.

F-4.4) Cord Assemblies:

Power Cord - Re

fi

 ll the cooling oil as outlined in paragraph 

F-1.3. Make wire connections as outlined in paragraph F-4.3. 
Insert female end of cord plug into housing bore aligning timing 

mark with hole in terminal block (21), see Figure 14. Compress 
cord plug with compression 

fl

 ange (16a) by tightening hex bolts 

(11) into the housing (6). Torque to 132 in-lbs.

SECTION: G REPLACEMENT PARTS

G-1 ORDERING REPLACEMENT PARTS:

When ordering replacement parts, ALWAYS furnish the 
following information:

1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.

6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.

G-2 PART NUMBER:

The part number consists of a six (6) digit number, which 
appears in the catalog. A one or two letter suf

fi

 x may follow 

this number to designate the design con

fi

 guration. This 

number is used for ordering and obtaining information.

G-3 MODEL NUMBER:

This designation consists of numbers and letters which 
represent the discharge size, series, horsepower, motor 
phase and voltage, speed and pump design. This number is 
used for ordering and obtaining information.

G-4 SERIAL NUMBER:

The serial number block will consist of a six digit number, 
which is speci

fi

 c to each pump and may be preceded by 

a alpha character, which indicates the plant location. This 
number will also be suf

fi

 xed with a four digit number, which 

indicates the date the unit was built (Date Code). 

EXAMPLE: A012345 0490.

Reference the six digit portion (Serial Number) of this number 
when referring to the product.

FIGURE 13

RETURNED GOODS

RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”.

CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR.

 

 

 

Products Returned Must Be Cleaned, Sanitized, 

 

 

 

Or Decontaminated As Necessary Prior To Shipment, 

 

 

 

To Insure That Employees Will Not Be Exposed To Health

 

 

 

Hazards In Handling Said Material. All Applicable Laws 

   And 

Regulations 

Shall 

Apply.

IMPORTANT!

WARRANTY REGISTRATION

Your product is covered by the enclosed Warranty.

Complete the Warranty Registration Form and return to Crane Pumps & Systems, Inc. 

Warranty Service Group If you have a claim under the provision of the warranty, contact 

your local Crane Pumps & Systems, Inc. Distributor.

Summary of Contents for 3SF-L Series

Page 1: ...nstant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton...

Page 2: ...PLODED VIEW Fig 16 15 PARTS LIST 16 17 RETURNED GOODS POLICY 12 WARRANTY 18 START UP REPORT 21 22 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL...

Page 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Page 4: ...1750 RPM 60Hz nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design NEMA L Single phase Torque Cur...

Page 5: ...elief SPEED 1750 RPM 60Hz nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design NEMA L Single phas...

Page 6: ...is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and place...

Page 7: ...e made in accordance with all applicord electric codes It is recommended that a junction box if used be mounted outside the sump or be of at least Nema 4 EEMAC 4 construction if located within the wet...

Page 8: ...be expected to operate for years on normal sewage pumping without failing However as with any mechanical piece of equipment a preventive maintenance program is recommended and suggested to include th...

Page 9: ...il Circulating 22 Imperial Oil Voltesso 35 Shell Canada Transformer 10 Texaco Diala Oil AX Woco Premium 100 F 2 Impeller and Volute Service F 2 1 Disassembly and Inspection To clean out volute 1 or re...

Page 10: ...ed or resting on bellows tail Slide retaining ring 28d over shaft and let rest on spring 28c Replace snap ring 32 in groove of shaft Set square ring 27 in groove on outer seal plate 29 and place outer...

Page 11: ...e bearing only until bearing seats against the retaining ring 24 Included with motor Motor Slide lower bearing 25 and motor shaft squarely into the seal plate 5 until bearing seats on the bottom Place...

Page 12: ...mation G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for orde...

Page 13: ...dom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction...

Page 14: ...14 FIGURE 15...

Page 15: ...15 FIGURE 16...

Page 16: ...g 24 1 085326 Retaining Ring Included with motor 25 1 017414 Bearing 26 4 1 135 1 Cap Screw 5 16 18 x 1 75 Lg Stainless 27 1 027269 Square Ring 28 1 Shaft Seal 005080 Carbon Ceramic Buna N 005080SB Tu...

Page 17: ...2 Discharge 3 8 Stainless 47 2 084948 Socket Head Cap Screw 1 4 20 x 1 25 Lg Stainless 60 A R Loctite 603 65 1 625 02117 Sleeve Fiberglass 66 1 030068 Jam Nut 20 S S TABLE 2 POWER CORD SETS CABLE LEN...

Page 18: ...PXVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SH...

Page 19: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Page 20: ...20 Notes...

Reviews: