background image

33

A Crane Co. Company

420 Third Street 

83 West Drive, Bramton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Limited 5 Year Warranty

Municipal Wastewater

Crane Pumps & Systems

 

offers a Commercial Warranty covering parts and labor on its pumps to this original end purchaser, when 

used in permanent installations in compliance with requirements of the Barnes Catalog and Technical Manual specifications for 

pumping municipal wasterwater or similar abrasive free, non corrosive liquids against defects in workmanship and material for the 

period as defined below.

In the event that the pump is provided with moisture and/or temperature sensors, these must be in use in order to validate this 

warranty. Barnes SH series Non-Clogs, SE series Non-Clogs, Wet End of XSE series Non-Clogs (Motor has a one (1) year warranty 

and is the sole responsibilty of Reliance Electric), Effluent and Sump pump models are Warranted for sixty (60) months (or 10,000 

hours of operation) from the date of manufacture from Crane Pumps & Systems to the End Purchaser as follows: Crane Pumps & 

Systems will pay the following share of the cost of replacement parts and labor provided the pump, with cable attached, is returned 

prepaid to an Authorized Service Station as decided by Crane Pumps & Systems and its Municipal Market Distributor.

Warranty Period *

 

Time After Manufacture (months):   0 - 18  

19 -39  

40 -60

 

Run Time (hours):  

0 - 3,000  

3,001 - 6,500    

6,501 - 10,000

 

Warranty:  

100%  

50%  

 

25%

* Time After Manufacture (months) or Run Time (hours) shall be determined by an Authorized Service Station and/or current copy of 

maintenance. If run time documentation cannot be produced then date of manufacture prevails.

Start-up reports and electrical system schematics (including Bills-of-Material) may be required to support any Warranty claims. 

This Warranty shall not apply to any product or part of product which has been subject to misuses, negligence, accident, operation 

outside of our published hydraulic curve parameters, used in a manner contrary to printed Instructions, or damaged due to a 

defective power supply, improper electrical protection, excessive abrasive wear or faulty installation or repair. 

THE SOLE AND 

EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY PRODUCT SHALL BE TO 

REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR AUTHORIZED REPAIR STATION, SUCH 

PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE NO FURTHER LIABILITY, WHETHER BASED ON 

WARRANTY, NEGLIGENCE OR OTHERWISE.

Crane Pumps & Systems neither assumes nor authorizes any person or company to assume for it, any other obligation in correction 

with the sale of its equipment. Any enlargement or modification of this Warranty by a Representative or other Selling Agent shall 

become HIS or HER exclusive responsiblity.

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, 

INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, RENTED EQUIPMENT, OUTSIDE CONTRACTOR FEES, UNAUTHORIZED 

REPAIR SHOP EXPENSES, LOST PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, 

WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN 

SHIPMENT. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

The following information must be completed to validate warranty. (Certain data will be provided before order placement and 

additional data following shipment).

Pump Model/Serial #:  _______________________________  Job Name: ___________________________________

Sales Order #:  ____________________________________  Date: _______________________________________ 

Factory Authorized Signature:  ________________________________________ Title:  _______________________

Summary of Contents for 3SCM

Page 1: ...56 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 133030S Rev H 3SCM Monovane Pumps 3 7 5HP 1750RPM 4SCM Monovane Pumps 3 10H...

Page 2: ...SHOOTING 16 SC CROSS SECTIONS Fig 9 EXPLODED VIEWS Fig 10 17 18 PARTS LISTS AND KITS 19 31 WARRANTY 33 RETURNED GOODS POLICY 34 WARRANTY REGISTRATION 34 START UP REPORT 35 36 Other brand and product...

Page 3: ...sert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...r Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION B INSTALLATION B 1 Location These self contained pumping units are recommended for use in a sump lift station or basin This pump i...

Page 5: ...s into the clamping plate Slowly tighten the two screws alternating back and forth until the clamping plate is drawn down flush to the top of the cord boss on the pump The two screws should be torqued...

Page 6: ...8 6 46 2 125497 2 88 3SCMPA5054 5 0 575 3 60 1750 J 6 0 6 9 37 0 125497 12 4 18 4 86 02 4 32 3SCMPA75N4 7 5 208 3 60 1750 H 23 8 28 5 105 9 123 6 125496 12 4 18 4 86 02 0 43 230 23 7 27 2 0 43 460 11...

Page 7: ...MC Pump 4SCMC50N4 5 0 208 3 60 1750 J 15 8 18 7 82 4 92 4 125496 12 4 18 4 86 02 0 72 230 15 0 17 2 125496 12 4 18 4 86 02 0 72 460 7 5 8 6 46 2 125497 12 4 18 4 86 02 2 88 4SCMC5054 5 0 575 3 60 1750...

Page 8: ...4SCDG50N4 5 0 208 3 60 1750 J 15 8 18 7 82 4 92 4 125496 12 4 18 4 86 02 0 72 230 15 0 17 2 125496 12 4 18 4 86 02 0 72 460 7 5 8 6 46 2 125497 12 4 18 4 86 02 2 88 4SCDG5054 5 0 575 3 60 1750 J 6 0 6...

Page 9: ...r MOISTURE AND TEMPERATURE SENSORS MOISTURE AND TEMPERATURE SENSORS Power Cable Power Cable Lead ID Lead ID Brown P1 Temperature Sensor Yellow P2 Temperature Sensor Orange W1 Moisture Sensor Blue W2 M...

Page 10: ...IRCUIT Single Phase Cap Chart HP RPM Cap Kit Start Relay Start Cap Run Cap 5 1750 133042 Mars 64 440MFD 330V 50MFD 370V 5 3450 141361 Mars 64 297MFD 330V 40MFD 440V 3 1750 2 1750 Single Phase Start Co...

Page 11: ...0 220 240 2 00 18 0 B 4 4 Moisture Sensors A normally open N O detector is installed in the pump seal chamber which will detect any moisture present and a continuity test resistor built into the motor...

Page 12: ...for a three phase installation interchange any two power cable leads at the control box Recheck the kickback rotation again by momentarily applying power C 2 2 Test Procedure For Moisture Sensor Cont...

Page 13: ...k is done to the pump CAUTION Operating pump builds up heat and pressure allow time for pump to cool to room temperature before handling or servicing E 1 Lubrication E 1 1 Checking Oil 1 Place pump on...

Page 14: ...or shaft then retaining ring 5 spring 4C and rotating member 4B from shaft See Figure 6 Examine all seal parts and especially contact faces Inspect seal for signs of wear such as uneven wear pattern o...

Page 15: ...3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and...

Page 16: ...ller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Page 17: ...17 SC Pump Series Cross Section 4 5 9 3 2 7 11 8 6 10 8A OIL FILL FIGURE 9...

Page 18: ...18 FIGURE 10 SC Pump Series Exploded View 35 ITEMS NOT SHOWN 12 31 32...

Page 19: ...al Mechanical Type 21 1 5 C CE B 4B 1 133029SD Seal Mechanical Type 21 1 5 SC SC B 5 2 133048 Ring Retaining EXT 5100 420 SS 6 1 See Table Impeller Ductile Iron 6A 1 See Table Slicer Blade Stainless 4...

Page 20: ...en 6 Bar O Ring 8G 38 1 039462 Tie Cable 39 2 125855 Screw SHCS M5 x 0 8 x 8 Stainless Steel 40 2 134013 Connector Wire Clip 49 1 See Table Striker Plate 50 See Table Shims 51 8 143110 Screw SHCS M10...

Page 21: ...5499XC 30 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XF 50 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XJ 75 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XL 100 400 600 59 0 8 4 18 4 1 12in 28 4mm Volute Pi...

Page 22: ...KIT 142157 KIT 142633 4 KIT 142137 142174 259 4SCDF 4 INCH 4SCDG 5 INCH 129994SK 5 ASSY KIT 141601 ASSY KIT 141579 KIT 142633 5 KIT 141601 142174 260 141579 002 RED 141579 004 TAN 141579 010 BROWN 141...

Page 23: ...s Striker Plate Kit Volute Kit Striker Hardware Kit includes M10 Bolts qty 8 O ring Plate Spacing Kit includes Level 4 Cut Proof Gloves Spacer Gage Shim Stock Kit includes 0 002 Shims 12 0 004 Shims 1...

Page 24: ...6 10in 133052TG ASSY KIT 143277TG ASSY KIT 133052TG C 143277TG C 142136 142133 1000 150mm 5 91in 133052TH ASSY KIT 143277TH ASSY KIT 133052TH C 143277TH C 142136 142133 1000 145mm 5 71in 133052TJ ASS...

Page 25: ...F C 142126 142133 0750 170mm 6 69in 133044TG ASSY KIT 143288TG ASSY KIT 137223TG C 143288TG C 142126 142133 0750 S Impeller Trim Dia mm in Ductile Iron Slicer Blade Kit Nihard Slicer Blade Kit Kit Com...

Page 26: ...Jumper Wire Connector Clip 24 Orange Wire Jumper Seal Kit includes Lower Volute O Ring option 1 Lower Volute O Ring option 2 Lower Volute O Ring option 3 Seal Plate upper O ring and Stator Lower O ri...

Page 27: ...Seal Kit Bearing Kit Bearing Bracket Kit Hardware Kit Seal Plate Kit Terminal Block Kit Overhaul Kit Purchase Seal Kit and Hardware Kit Leg Kit includes 3 Legs painted attachement hardware Leg Kits Mo...

Page 28: ...r Shaft Snap Ring Rotor Stator Motor Housing Kit includes Motor Housing painted Pipe Plug Set Cap Screw Stator Self clinching Tie Cable Cap Plug 1750 RPM Model No Motor Kit Part No SH 30N4 145663 SH 5...

Page 29: ...127SK ASSY KIT 142633 4 KIT 3SCMPA50N4 See Motor Kit Table 138579 143127SK KIT 138583 138610 138593 138615 138613 138614 S 125506 137223TB ASSY KIT 142157 KIT 142125 AS SY KIT 143127SK ASSY KIT 142633...

Page 30: ...133044 AS SY KIT 142157 KIT 142137 AS SY KIT 133033SK ASSY KIT 142633 4 KIT 4SCMS7554 133961 133962 138579 133033SK KIT 138584 138610 138593 138615 138613 138614 S 125506 133044 AS SY KIT 142157 KIT 1...

Page 31: ...133052 AS SY KIT 142157 KIT 142137 AS SY KIT 133033SK ASSY KIT 142633 4 KIT 4SCDF7554 133961 133962 138579 133033SK KIT 138584 138610 138593 138615 138613 138614 S 125506 133052 AS SY KIT 142157 KIT 1...

Page 32: ...Notes...

Page 33: ...upport any Warranty claims This Warranty shall not apply to any product or part of product which has been subject to misuses negligence accident operation outside of our published hydraulic curve para...

Page 34: ...Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration...

Page 35: ..._ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating _______________...

Page 36: ...ls installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___...