background image

ITEM

NAME

MATERIAL

1

CABLE 

STOW

2

MOTOR COVER 

AISI 316

3

MOTOR HOUSING 

AISI 316

4

OIL CHAMBER 

AISI 316

4-1

SEAL BRACKET 

AISI 316

5

VOLUTE 

AISI 316

6

IMPELLER

AISI 316

9

DISCHARGE ELBOW

AISI 316

10

FLANGE

AISI 316

11

MECHANICAL SEAL

SIC/SIC  CA/CE

12

LIP SEAL 

VITON

13-1

6306 BEARING 

NTN/TPI

13-2

6309 BEARING 

NTN/TPI

14

STATOR 

-

15

ROTOR WITH SHAFT 

AISI 316

16

O-RING

VITON

17

O-RING

VITON

18

FLANGE GASKET 

VITON

19

ELBOW GASKET 

VITON

21

OVERLOAD PROTECTOR 

KLIXON

23

SCREW OF CABLE GLAND 

AISI 316

24

HANDLE 

AISI 316

24-1

HEX. BOLT / SPRING WASHER 

AISI 316

25

SOCKET SCREW / O-RING

AISI 316 / VITON

26

HEX. BOLT / SPRING WASHER 

AISI 316

28

SPRING WASHER

AISI 316

29

HEX. NUT

AISI 316

30

KEY 

AISI 316

31

HEX. BOLT 

SC

32

HEX. BOLT / SPRING WASHER 

AISI 316

33

SOCKET SCREW / O-RING

AISI 316 / VITON

34

PHILLIPS SCREW 

SC

35

HEX. BOLT / SPRING WASHER 

AISI 316

37

HEX. BOLT / FLAT WASHER / HEX. NUT

AISI 316

38

TRUSS BOLT

SC

39

WAVE WASHER

SC

41

GROUND LEAD

-

43

BEARING HOLDER

SC

Repair Parts

16

4

10 HP

For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown 
on Parts List.

barmesapumps

Summary of Contents for BSV Series

Page 1: ...10 HP 3450 RPM Installation Operation Maintenance Manual Submersible Stainless Vortex Sewage Pump IMPORTANT Read all instructions in this manual before operating or servicing a pump Last update 12 13 2022 barmesapumps ...

Page 2: ...gled in moving parts Pumps build up heat and pressure during operation Allow time for pumps to cool DANGER before handling or servicing the pump or any accessory items associatedwithornearthepump Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpower tag Do not lift carry or hang pump by th...

Page 3: ...na N Viton PAINT Airdryenamel waterbased SEAL Double mechanical oil lubricated Upper part of carbon ceramic lower part ofsiliconecarbide Viton elastomerandstainlesssteelspring CORDENTRY 33ft 0 5 7 5HP 40ft 10HP ofneoprenecord BEARINGS Ball single row permanently oil lubricated for 60 000 hours of work Designedforradialandaxialloads MOTOR 1 3 phase 115 230 460 volts 60 Hz 3450 RPM For continuous du...

Page 4: ...5 4 5 9 4 3 3 5 3 5 5 4 5 9 4 7 3 9 MODEL HP VOLTS PHASE MAX AMPS Ø DISCHARGE DISCHARGE MAX m MAX FLOW GPM CORD ft SPH SLD HNDLG 2BSV 051DS 0 5 115 1 8 2 11 88 33 1 35 2BSV 054DS 0 5 460 3 1 4 2 11 88 33 1 35 2BSV 101DS 1 115 1 12 2 14 118 33 1 35 2BSV 102DS 1 230 1 6 2 14 118 33 1 35 2BSV 103DS 1 230 3 4 2 14 118 33 1 35 2BSV 104DS 1 460 3 2 2 14 118 33 1 35 Built in capacitor for single phase mo...

Page 5: ...3 4 7 2 0 4 6 1 5 9 8 2 4 1 4 1 4 1 15 4 15 4 4 1 9 3 5 9 6 1 9 3 5 3 5 2 5 2 5 3 MODEL HP VOLTS PHASE MAX AMPS Ø DISCHARGE DISCHARGE MAX m MAX FLOW GPM CORD ft SPH SLD HNDLG 2BSV 202DS 2 230 1 11 2 20 155 8 33 1 75 2BSV 203DS 2 230 3 7 2 20 155 8 33 1 75 2BSV 204DS 2 460 3 3 5 2 20 155 8 33 1 75 2BSV 303DS 3 230 3 8 2 23 177 33 1 75 2BSV 304DS 3 460 3 4 5 2 23 177 33 1 75 Built in capacitor for s...

Page 6: ...ions Dimensions 45 7 5 HP 5 MODEL A A1 A2 A3 B B1 B2 D D1 D2 D3 D4 D5 3BSV 503DS 3BSV 504DS 3BSV 753DS 3BSV 754DS MODEL D6 DN E F G P P1 P2 H H1 H2 H3 WT 3BSV 503DS 3BSV 504DS 3BSV 753DS 3BSV 754DS Dimensions in inches WT Weight in pounds without cable 20 6 3 8 9 118 6 0 6 0 6 90 45 90 5 9 3 0 6 0 6 0 6 90 45 90 26 5 5 9 3 0 6 24 9 18 4 6 3 8 9 105 8 5 5 5 9 3 7 3 7 4 5 7 2 5 6 5 6 6 1 5 3 6 1 5 3...

Page 7: ...4 0 6 0 7 0 6 0 6 90 45 90 45 24 8 20 3 7 1 10 3 156 5 Dimensions in inches WT Weight in pounds without cable MODEL HP VOLTS PHASE MAX AMPS Ø DISCHARGE DISCHARGE MAX ft MAX FLOW GPM CORD ft SPH SLD HNDLG 4BSV1003DS 10 230 3 28 4 128 300 47 1 75 4BSV1004DS 10 460 3 14 4 128 300 47 1 75 410 HP Specifications Dimensions 6 barmesapumps ...

Page 8: ...1 F2 G 5 3 6 8 5 3 6 8 5 5 5 9 3 9 90 45 90 7 1 5 9 15 9 9 5 7 1 7 5 G1 H H1 H2 H3 H4 H5 H6 H7 H8 H9 I J K L WT WT1 2 8 29 24 4 11 3 4 1 8 1 12 4 12 5 0 4 8 7 1 0 6 0 6 0 7 0 6 156 5 30 6 Dimensions in inches WT Weight in pounds without cable WT1 Slide Rail Coupling weight 410 HP with Slide Rail Coupling Specifications Dimensions 7 barmesapumps ...

Page 9: ...e least turbulence 3 If there is a flow of liquid inside the tank support the piping where appropriate Install piping so that air will not be entrapped If piping must be installed in such a way that air pockets are unavoidable install an air release valve wherever such air pockets are most likely to develop 4 Do not permit end of discharge piping to be submerged as backflow will result when the pu...

Page 10: ...iary Capacitor Single phase automatic L N PE Black Brown White Blue Green Yellow Green Ground Green Yellow Green Yellow Frame grounding Thermal protector Main Auxiliary Capacitor Float switch Three phase R S T Frame grounding Green Yellow Ground PE Red White Black Green Yellow Green U V W U2 V2 W2 Overload protector Electrical Wiring 9 barmesapumps ...

Page 11: ...ller plug on top Inject suitable amount turbine oil no 32 ISO VG 32 Inspections at 3 5 year intervals Conduct an overhaul of the pump These intervals will preclude the possibility of future trouble Parts that will need to be replaced Replace the appropriate part when the following conditions are apparent See figure 4 Note replacement schedule is based on normal operating conditions REPLACEABLE PAR...

Page 12: ...Name Plate and Part Description and Part Number as shown on Parts List 40 5 1 HP 11 22 22 1 1 3 2 19 3 19 6 22 19 6 18 4 6 19 2 5 7 19 4 15 1 15 2 19 9 23 13 14 17 1 17 2 8 9 10 24 21 6 20 4 22 1 20 7 31 1 19 7 20 7 19 6 21 6 20 5 11 27 18 2 12 31 21 9 17 3 21 6 17 4 barmesapumps ...

Page 13: ...TOR GASKET VITON 10 OIL SEAL VITON 18 2 FLANGE GASKET VITON 11 IMPELLER SUS 316 27 FLANGE SUS 316 12 ITEM NAME MATERIAL 1 CABLE SJTOW STOW 5 STATOR WITH MOTOR HOUSING SUS 316 17 4 O RING OF OIL CHAMBER NBR 19 2 LONG SCREW OF MOTOR STEEL 19 3 SCREW OF CABLE GLAND SUS 316 19 4 SCREW STEEL 19 6 SCREW SUS 316 19 7 SCREW OF FLANGE SUS 316 19 9 SCREW OF PROTECTOR STEEL 20 4 WASHER STEEL ITEM NAME MATERI...

Page 14: ... 3 23 1 19 9 31 2 13 14 19 10 4 18 21 6 6 19 2 5 35 19 6 7 8 22 19 6 9 21 6 20 5 12 18 2 19 7 27 18 1 11 19 8 17 10 24 20 7 31 1 20 7 22 1 21 6 22 1 31 21 9 28 17 3 2 19 1 20 7 15 1 15 2 22 3 21 19 3 1 19 9 31 2 23 13 19 10 4 18 21 6 6 19 2 5 35 19 6 7 8 22 19 6 9 21 6 11 17 1 17 2 10 24 22 1 21 6 22 1 2 19 6 20 5 31 21 9 17 3 18 1 12 20 7 31 1 18 2 27 20 7 19 7 28 20 7 19 8 19 barmesapumps ...

Page 15: ... HP SUS 316 FLANGE GASKET 5 7 5 HP 14 ITEM NAME MATERIAL ITEM NAME MATERIAL 1 CABLE SJTOW STOW 19 10 SCREW SUS 316 5 STATOR WITH MOTOR HOUSING SUS 316 20 5 WASHER OF IMPELLER SUS 316 14 CAPACITOR 1 PHASE 20 7 WASHER SUS 316 15 1 15 2 BEARINGS 21 SPRING WASHER OF HANDLE SUS 316 17 1 17 2 O RINGS VITON 21 6 SPRING WASHER SUS 316 17 3 O RING OF VOLUTE VITON 21 9 SPRING WASHER OF IMPELLER SUS 316 19 S...

Page 16: ...For repair part please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List Repair Parts 15 410 HP barmesapumps ...

Page 17: ...IXON 23 SCREW OF CABLE GLAND AISI 316 24 HANDLE AISI 316 24 1 HEX BOLT SPRING WASHER AISI 316 25 SOCKET SCREW O RING AISI 316 VITON 26 HEX BOLT SPRING WASHER AISI 316 28 SPRING WASHER AISI 316 29 HEX NUT AISI 316 30 KEY AISI 316 31 HEX BOLT SC 32 HEX BOLT SPRING WASHER AISI 316 33 SOCKET SCREW O RING AISI 316 VITON 34 PHILLIPS SCREW SC 35 HEX BOLT SPRING WASHER AISI 316 37 HEX BOLT FLAT WASHER HEX...

Page 18: ...nd caused pump to stop 2 High liquid temperature has activated motor protector and caused pump to stop 3 Reverse rotation 1 Raise water level to C W L 2 Lower liquid temperature 3 Correct rotation Does not pump Inadequate volume 1 Reverse rotation 2 Significant drop in voltage 3 Operating a 60 Hz pump with 50 Hz 4 Discharge head is high 5 Large piping loss 6 Low operating water level causes air su...

Page 19: ...ht to have the product returned to our factory for additional testing This warranty shall not apply when damage is caused by 1 improper installation 2 improper voltage 3 lightning 4 excessive sand or other abrasive material 5 corrosion build up due to excessive chemical content or 6 uncontrollable acts of god Any modification of the original equipment will also void the warranty We will not be res...