background image

To reassemble, clean the threads with 

thread  locking  compound  cleaner. 
Apply  removable  Loctite®  242  or 
equivalent  to  shaft  threads.  Screw 

impeller  onto  the  shaft  hand  tight 

while  using  a  screwdriver  in  the  slot 

at  the  end  of  the  shaft  to  hold  it 
stationary.  Rotate  impeller  to  check 
for binding. Install U-cup by applying 

adhesive  to  bore  of  volute.  Be  sure 
not  to  get  adhesive  on  inside 

diameter of U-cup.

Position  lock  washer  on  cap  screw 
and screw into volute. Torque to 100 
in/lbs.  Check  for  free  rotation  of 

impeller.

Shaft Seal:

To  examine  or  replace  shaft  seal, 
disassemble  volute  and  impeller  as 

stated. Remove retaining ring, spring 
and rotating member from shaft.

Inspect seal for signs of uneven wear 
pattern on stationary members, chips 
and scratches on either seal face. 

DO 

NOT interchange seal components, 
replace  the  entire  shaft  seal

 

.  If

replacing  seal,  remove  stationary  by 
prying out with  lat screwdrive . 

f

r

Motor,  Capacitor  and  Bearings:

 

Remove  volute  and  impeller  as 
previously  stated  and  drain  oil  from 

housing.  Remove  shaft  seal.  Position 

unit  upright,  using  blocks  to  avoid 
resting  unit  on  shaft.  Unscrew  cable 

cap screws and remove compression 

flange and power cord. Remove snap 

ring with a flat head screwdriver.

Nothing should come in contact with 

the seal face except the seal tool. Be 
sure  the  stationary  is  in  straight. 
Lightly oil 

(Do not use grease)

 shaft 

and  inner  surface  of  bellows.  Slide 

rotating  member  onto  stationary 
using  a  seal  tool.  Place  spring  and 

retaining ring onto rotating member. 
Assemble  impeller  and  volute  as 
described.

Place  stator  over  rotor,  lining  up 
motor  bolts  with  holes  in  seal  plate. 

Place  spring  washer  on  bearing  and 
cover  onto  rotor/stator  assembly. 

Position capacitor so that it will lay on 

the  opposite  side  of  the  cable  entry 

boss  of  the  housing.  Install  bracket 

and  reconnect  capacitor  leads. 
Torque  motor  bolts  to  in/lbs.  Set 
square ring in grove on seal plate.

Slide  rotor/shaft  with  bearings  and 
into seal plate until bearing seats into 

seal  plate.  Install  snap  ring  into  seal 

plate.

Remove  cap  screws  from  seal  plate 

and  lift  housing  from  seal  plate. 
Remove square ring, replace if cut or 

damaged. Disconnect capacitor leads 
from  capacitor.  Remove  motor  bolts, 
lift  cover,  body  and  stator  assembly 

from seal plate. Remove snap ring to 
remove  rotor  assembly.  Remove 
bearings and with a wheel puller.

Handle  seal  parts  with 
extreme  care.  DO  NOT 
damage  lapped  surfaces.

06

Service

Position gasket on volute flange and 

position impeller and motor housing 

assembly on volute.

CAUTION

Be sure the inside lip of 

the U-cup is not pushed out of place 

when assembling volute to rest of the 
pump.

To  reassemble,  clean  seal  cavity  in 
seal  plate  and  oil.  Press  seal’s 

stationary  member  firmly  into  seal 

plate, use a seal tool or pipe.

Pull  the  terminal  block  out  of  the 
housing  using  a  T-bolt  or  a  pair  of 

pliers  and  a  .25-20  screw  in  the 

threads  of  the  terminal  block.  Leave 
slack  on  the  motor  leads  connected 
underneath.  Use  needle  nose  pliers 
to  pull  each  female  connector  off  of 

the  pins  on  the  underside  of  the 
terminal block. The voltage should be 
noted. 

Check motor capacitor with an Ohm 
meter  by  first  grounding  the 

capacitor  by  placing  a  screwdriver 
across  both  terminals  and  then 

removing  screwdriver.  Connect  Ohm 

meter (set on high scale) to terminals. 
If  needle  moves  to  infinity  (∞)  then 
drifts back, the capacitor is good. 

If needle does not move or moves to 

infinity  (∞)  and  does  not  drift  back, 
replace  capacitor.  Inspect  motor 
winding  for  shorts  and  check 

resistance  values.  Check  rotor  for 

wear.  If  rotor  or  the  stator  windings 

are  defective,  the  complete  motor 
must be replaced.

Lower housing down onto seal plate  

while  aligning  holes  and  stringing 
motor  leads  through  the  cord  entry 
bore.  Place  cap  screws  through  seal 
plate  into  housing  and  torque  to  60 

in/lbs. Reconnect motor leads to the 
underside of the terminal block.

Place  o-ring  into  groove  in  terminal 
block and lubricate with dielectric oil. 
Press  the  terminal  block  into  the 

housing so it seats completely below 
the snap ring groove. Place snap ring 
into  groove  in  cord  entry  bore  of 

housing.

barmesapumps.com

Power Cable Connection:

Check  power  cord  for  cracks  or 
damage and replace if required. Refill 
the  cooling  oil.  Insert  female  end  of 

cord plug into housing bore aligning 

timing  markwith  hole  in  terminal 
block.  Compress  cord  plug  with 
compression  flange  by  tightening 

cap screws with lock washers into the 

housing. Torque to 132 in/lbs.

Summary of Contents for BPSTEP1022

Page 1: ...Installation Operation Maintenance Manual Submersible Effluent Pumps BPSTEP 0 5 1 HP 3450 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Page 2: ...atedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce r...

Page 3: ...MA 48class30 SEALPLATE CastironASTMA 48class30 IMPELLER Singlevaneenclosed Polypropylenewithstainlesssteelinsert SHAFT Stainlesssteel O RINGS SquareshapedBuna N PAINT Airdryenamel waterbased SEAL Outb...

Page 4: ...l NOT be installed in locations classified as hazardous in accordance with the National Electrical Code NEC ANSI NFPA 70 or Canadian Electric Code CEC The pump should never be installed in a trench di...

Page 5: ...t or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 Wire Size If longer power cable is required c a...

Page 6: ...after five minutes the pressure is still holding constant and no bubbles oil seepage is observed slowly bleed the pressure and remove the gauge assembly Replace oil Leek must be located and repaired...

Page 7: ...ring replace if cut or damaged Disconnect capacitor leads from capacitor Remove motor bolts lift cover body and stator assembly from seal plate Remove snap ring to remove rotor assembly Remove bearing...

Page 8: ...07 Repair Parts BPSTEP For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesapumps com...

Page 9: ...plate 1 HT200 16 Impeller 117 3 1 Polypropylene 17 Casing 1 HT200 18 U shpe ring 31 5 x 44 3 x 6 5 1 NBR40 19 Casing sealing washer 1 Rubber 20 Hex socket cap screws 1 4 20UNCx28 2 304 21 V shape ring...

Page 10: ...e any two of three power supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of dis...

Page 11: ......

Page 12: ......

Reviews: