Description
The non-self priming vertical multi-stage centrifugal pump is driven by a standard electric motor. The motor
output shaft directly connects with the pump shaft through a coupling. The pressure-resistant cylinder and
flow passage components are fixed between pump head and inlet & outlet section with stay bolts. The inlet
and outlet are located at the pump bottom at the same plane. This kind of pump can be equipped with an
intelligent protector to effectively prevent it from dry-running, out-of-phase and overload.
Features
High efficient
Low noise
A little corrosive liquid resistance
Compact structure
Good appearance
Small volume
Light weight
Easy to service
Good seal performance
etc.
Applications
Pumped liquids: low viscosity, neutral, non-explosive liquids, not containing solid particles or fibres. The
liquid must not attack the pump materials chemically.
Boiler water supply and condensing system.
Water treatment, filtration system.
Food and beverage industries.
Pressure boosting in high-rise buildings.
Farmland irrigation, nursery irrigation and golf court irrigation.
Industry cleaning system.
Liquid conveying, circulation and boosting.
Hot and cool water.
Operation conditions
Medium temperature: normal temperature type -15° C ~ +70° C.
Hot water type -15° C ~ +120° C.
Flow: 0.4 ~ 180 m³/h.
Medium pH range: pH 5 - 9.
Maximum ambient temperature: +40° C.
Maximum altitude: 1000 m.
Minimum inlet pressure: Refer to BMV catalog.
When pumping liquids with a density and/or viscosity higher than that of water, use motors
with correspondingly higher outputs, if required.
02
Applications & Conditions
CAUTION