6 Installation/Commissioning

 

 

DANGER 

Only install or uninstall the switch when deenergized (electrically and hydraulically/pneumatically).

 

Pressure connection and electrical connection must be carried out by trained or instructed 
personnel according to state-of-the-art standards.

 

The switch must only be installed in systems where the maximum pressure P

max

 is not exceeded 

(see type label).

 

 

 

WARNING

 

Pressure peaks and pressure shocks exceeding the maximum operating pressure are 
inadmissible.

 

The maximum operating pressure is the upper final value of the adjustable range or, if specified, 
the pressure indicated as maximum operating pressure. Exceeding the max. operating pressure 
affects the performance and the life span of the product and may damage it.

 

Pressure switches must be mounted vibrationless.

 

 

 

WARNING

 

Check the switch regularly for functioning.

 

If the switch does not work properly, stop operation immediately!

 

 

 

IMPORTANT

 

The standard flange version (CETOP) can be mounted directly on the hydraulic blocks. For pipe 
connection mounting blocks (see Fig. 9) with two or four bores are available for wall mounting 
(ø5.6 mm).

 

 

 

IMPORTANT

 

All pressure switches are tested for proper functioning before they leave the factory. The factory 
proof pressures are stated on the type plate.

 

Contact Protection

 

The micro switches used are normally suitable for both direct and alternating current operation. 
Inductive, capacitive and lamp loads may, however, considerably reduce the life expectancy of a 
micro switch and, under extreme circumstances, even damage the contacts. 

 

Depending on the application spark suppression and current limiting is recommended (see 
succeeding figures).

 

 

 

 

 

Fig. 1:  Protection in case of  capacitive loads     

R1:  Protection against starting current 
rushes R2,R3:  Protection against high 
discharge currents

 

Fig. 2:   Lamp load provided with resistance in 

parallel or series connection to switch 
of condensators

 

 

 

Fig. 3:   Protection in case of  continuous 

current  and inductive load by recovery 
diode

 

Fig. 4:   Protection in case of alternating  

current and inductive load by RC-link

 

Set point adjustment 

 

IMPORTANT

 

Factory-Provided: pressure (temperature) switch point setting 
We confirm for pressure (temperature) switches that have been factory set the setting will be 
detailed on the label name plate. 

Warranty is not applicable for any changes that may occur due to transportation or installation. 
For critical applications we recommend the setting is checked and re-set if cecessary after 
installation and wirding of the pressure (temperature) switch.

 

 
In pressure switches, a displacement of the pressure sensing element occurs with a change in 
pressure. Following the displacement of the pressure sensing element operates a microswitch.

 

Upon delivery of the product, the set points are likely to be found in the middle of the adjustable 
range. On request, fix set points may be adjusted by our factory. In this event, the point will be 
indicated on the type plate or any separate plate, i = increasing, d = decreasing.

 

 

 

 

5

 

4

 

MS

R1

R2

R3

Load

C cable

MS

R

R

 

MS

 

MS

 

U

 

=

 

Diode

 

Load

 

MS

 

U

 

c

 

Load

 

R

 