PRE-CLEANING CHECKLIST
•
Identify the cases that need to be cleaned (Note: Multiple cases usually run on the same refrig
eration circuit, so plan on cleaning all cases on that circuit at one time)
•
Post safety signs in the area of the cases that are going to be cleaned
•
Remove the product from the cases and relocate to a refrigerated storage area
•
Turn off the refrigeration to the cases, there are several options:
•
Turn off at the power supply
•
If your case is equipped with a clean switch button, push the button. The push button allows for a
90 minute delay and will automatically turn back on after 90 minutes
•
If your case is equipped with a cleaning toggle switch, fl ip the manual toggle off to clean and
manually fl ip back on when case is cleaned
•
If you are unable to turn the refrigeration off to the case by the above methods, put the case in a
manual defrost through the Dixell Controller
Push the DOWN key for more than 2 seconds and a manual defrost will start on the Dixell Con
troller. The controller must be turned back on when fi nished cleaning.
•
If your case is equipped by a different type of controller, refer to the controller manual for putting
the case into manual defrost for case cleaning
•
Turn off the electrical circuits to the case at the power supply
•
Wait until the Coolgenix deck pans are room temperature before removing - the center pan will have
a sensor (Fig. 12) attached on the bottom of the deck pan, detach the sensor before removing the
pan
•
Visually inspect the cases for debris and ice
•
Check the drain to make sure it is not clogged
Before cleaning a Coolgenix case, be certain that all of the steps listed below
have been completed to ensure proper case functionality, safety and compliance
with warranty terms.