background image

5

R5906676 /01

X-series

LED components used in X-series tiles are ESD (Electro-Static Discharge) sensitive. To prevent the possibility of destroying LED
components do not touch either in operation or while switched off. Always use ESD-gloves.

Risk of electric shock / Risk of fire:

To protect against risk of fire caused by overloading of power cables, the number of tiles connected in parallel is limited. See table below.

Tile

Power source

Maximum number of tiles per power source cable

X1.6

100-180 VAC

8 tiles

X1.6

180-240 VAC

15 tiles

X1.9

100-180 VAC

10 tiles

X1.9

180-240 VAC

17 tiles

X2

100-180 VAC

11 tiles

X2

180-240 VAC

21 tiles

X4

100-180 VAC

11 tiles

X4

180-240 VAC

21 tiles

Each power source cable should be protected by a circuit breaker or fuses rated 16 A / 250 VAC (15 A / 250 VAC in the USA and
Canada). Note that one tile requires 100-240 VAC, 16 A, 50-60 Hz, X2: 0.55 A at 230 VAC, X1.6: 0.85 A at 230 VAC

Disconnect device:

When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall be installed near the
equipment and be easily accessible, or a readily accessible general disconnect device shall be incorporated in the fixed wiring.

This equipment MUST be earthed:

In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding type
plug will expose you to the risk of electric shock.

Power system:

It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical installation
should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and Ground Fault Current
Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special attention should be given
to HD 60364, Harmonization Document for electrical installation of buildings. In Germany VDE 0100 should be adhered to. In America,
special attention should be given to the National Electrical Code, ANSI/NFPA 70.

Mains cords:

The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power cords are
damaged, replace them only with new ones. Never try to repair a power cord.

LED's:

The LED's used on the X-series tiles are fragile. Never push with a hard or sharp object onto the lens of the LED as this may cause
damage to the LED. The maximum allowed load upon the lens of the LED is 300 gram/LED. Be careful when installing a shader upon the
X-series tiles. Shaders only fit in one direction and this should be verified before pushing into final position. Use your bare fingers (not
nails) to press the shader over the LED's. Use your finger nails to press upon the framework of the shader between the LED's (not upon
the LED's) to push the shader in its final position.

Do not hot plug:

Do not hot plug any cables. Damage to the connector pins may occur. Resulting damage is not covered under warranty.

Maximum allowed display height:

The maximum height of a X-series display in a base stand configuration is 9 tiles X1.x or 10 tiles X2. The maximum height of a X-series
display in a hanging (truss) configuration is 16 tiles.

1.4 Proper usage

Proper usage of X-series tiles

No part of the X-series tile can come in contact with any type of moisture.

No part of the X-series tile can come in contact with any type of abrasive.

No part of the X-series tile can come in contact with any type of dust.

No part of the X-series tile can come in contact with any type of corrosive substance.

Using the LED product in an environment with high corrosive gasses (e.g. Sulphur) can lead to discoloration of the materials. This
discoloration gives a change in brightness of the product. This could lead to uniformity differences and possibly also to failures. Each
use of the product in this kind of environment needs to be checked up-front with the supplier.

X-series tiles are to be used in environments meeting the operating specifications.

X-series tiles are not to be used in environments that are subject to airborne contaminants such as that produced by smoke machines
(cracked oil) or similar (these deposit a thin layer of greasy residue upon the LED's optics, degrading performance).

X-series tiles are not to be exposed to extreme localized heat or cold exceeding the temperature specifications.

Safety

Summary of Contents for X Series

Page 1: ...ENABLING BRIGHT OUTCOMES Safety manual X series ...

Page 2: ...istered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ...fied technical personnel only Accredited safety officers must ensure the safety of the site construction assembly connection use dismantling transport etc of such safety critical systems Notice on safety This equipment is built in accordance with the requirements of the international safety standards IEC60950 1 EN60950 1 UL60950 1 and CAN CSA C22 2 No 60950 1 which are the safety standards of info...

Page 4: ...s or provide suitable additional lightning protection Unplug this apparatus when unused for long period of time Refer all servicing to qualified service technicians personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged the apparatus does not operate normally or has been dropped Use only with systems or peripherals specified by t...

Page 5: ...ectrical Code ANSI NFPA 70 Mains cords The power cords delivered with this system have special properties for safety They are not user serviceable If the power cords are damaged replace them only with new ones Never try to repair a power cord LED s The LED s used on the X series tiles are fragile Never push with a hard or sharp object onto the lens of the LED as this may cause damage to the LED Th...

Page 6: ...light cases or Barco single unit or multiple unit packaging Further even the use of custom flight cases or packaging material does not guarantee the X series tiles against damage due to excessive force of impacts X series packing material can be ordered at Barco All warranty claims regarding damaged X seriess due to incorrect packing will be rendered invalid X series tiles are not to be connected ...

Page 7: ...sposal service For details please visit the Barco website at http www barco com AboutBarco weee 2 2 RoHS compliance 中国大陆 RoHS Chinese Mainland RoHS 根据中国大陆 电器电子产品有害物质限制使用管理办法 也称为中国大陆RoHS 以下部分列出了Barco产品中可能包含的有毒和 或有害物质的名称和含量 中国大陆RoHS指令包含在中国信息产业部MCV标准 电子信息产品中有毒物质的限量要求 中 According to the Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Also...

Page 8: ... limit requirement in GB T 26572 10 在中国大陆销售的相应电子信息产品 EIP 都必须遵照中国大陆 电子电气产品有害物质限制使用标识要求 标 准贴上环保使用期限 EFUP 标签 Barco产品所采用的EFUP标签 请参阅实例 徽标内部的编号使用于指定产 品 基于中国大陆的 电子信息产品环保使用期限通则 标准 All Electronic Information Products EIP that are sold within Chinese Mainland must comply with the Marking for the restriction of the use of hazardous substances in electrical and electronic product of Chinese Mainland marked wi...

Page 9: ......

Page 10: ...www barco com R5906676 01 2021 09 01 ...

Reviews: