background image

1.  

 MSWU-81E Serial Communication 

MSWU-81E  

– 2014/10/30 

 

 

 

 

 

 

                                       

5

 

 

1.3   System Operation commands 

Introduction 

The Operation commands tell the projector what to do. All commands start with 2 letters: “op” for operations 
commands and a space [SP] then following a control command then finally the value wants to read, set, increase or 
decrease.  All commands must end with a carriage return (ASCII hex 0D), shown as [CR] below.  The syntax for 
operations commands is as follows: 

op[SP]<operation command>[SP]<Setting Value>[CR] 

For all but Execute functio

ns the response from the projector will be the command and “= <value>” where <value> is 

the current value or “NA” if the value is not available.  For Execute functions the response will be the same command.  
All responses will be in CAPS and also ending with a carriage return (ASCII hex 0D).  Please refer to the following table 
for command list and examples: 

System Operation Commands: 

Operation 

Commands 

Values 

Set 

= <value> 

Makes the unit take that value. 

Get 

Asks what the current value is. 

Increment 

Adds 1 to the current value. 

Decrement 

Subtracts 1 from the current value. 

Execute 

(none) 

Performs an action such as a reset. 

Motor operation command: 

For motor control like lens shift, focus and zoom, the parameters “ + ” and “ - ” are defined as follows. 

Command item  

command  

System Action  

focus 

+ - 

+ => Focus Near, 
- => Focus Far 

zoomio 

+ - 

+ => Zoom out 
- => Zoom in 

Vert.offset 

+ - 

+ => Up 
- => Down 

horiz.offset 

+ - 

+ => Right 
- => Left 

lens.center 

(execute) 

Midposition shift  

 

Get operations command example: 

 

Input: op bright? [CR] 

 

System Response: OP BRIGHT = 100  

 

Increase & Decrease operations command examples: 

 

Input: op  [CR] 

 

System Response: OP BRIGHT = 101 

 

Input: op bright - [CR] 

 

Response: OP BRIGHT = 126  

 

Set operations command example: 

 

Input: op bright = 127 [CR] 

 

System Response: OP BRIGHT = 127  

 

Execute command example: 

 

Input: op auto.img [CR] 

 

Response: OP AUTO.IMG 

 
 
 
 
 

Summary of Contents for RLS W12

Page 1: ...RLS W12 MSWU 81E ...

Page 2: ...Document version 00 Barco NV Projection Division Noordlaan 5 B 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco com esupport Visit us at the web www barco com ...

Page 3: ...ion MSWU 81E 2014 10 30 3 1 RLS W12 SERIAL COMMUNICATION About this chapter This chapter contains serial commands to control the projector Overview Interface and Requirements Cable Type and Pin definition System Operation commands ...

Page 4: ...be entered using a typical terminal emulator like Windows HyperTerminal with the following setting Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None TCP IP communication port The TCP IP communication port number 43680 1 2 Cable Type and Pin definition Diagram Note Use Straight through RS232 cable Pin 9 is reserved for service purpose only ...

Page 5: ...II hex 0D Please refer to the following table for command list and examples System Operation Commands Operation Commands Values Set value Makes the unit take that value Get Asks what the current value is Increment Adds 1 to the current value Decrement Subtracts 1 from the current value Execute none Performs an action such as a reset Motor operation command For motor control like lens shift focus a...

Page 6: ... 2 50 Hz 3 60 Hz Note2 3 auto powoff 0 Off 1 On 4 auto powon 0 Off 1 On 5 no signal 0 Logo 1 Blue 2 Black 3 White Note1 6 auto imgadj 0 Off 1 Auto 2 Always Note2 7 contrast 0 200 Note2 8 Bright 0 200 Note2 9 sharp 0 200 Note2 10 nr 0 200 Note2 11 color temp 0 3200K 1 5400K 2 6500K 3 9300K 4 Native Note2 Note8 12 red offset 0 200 Note2 13 green offset 0 200 Note2 14 blue offset 0 200 Note2 15 red g...

Page 7: ...3 VGA 4 YUV 1 5 RGBHV YUV2 6 Reserve 7 Reserve 8 Reserve 9 SDI HDSDI 3G Note1 Note9 28 pip pos 0 Top left 1 Top right 2 Bottom left 3 Bottom right 4 Split L R Note1 Note10 29 pip 0 Off 1 On Note1 30 lamp mode 0 Economy 1 Standard 2 Dimming Note2 31 lamps 0 Single 1 Dual Note1 Note11 32 altitude 0 Off 1 On Note1 33 lamp pwr W7 0 75 20 100 H8 0 80 20 100 Note2 34 lamp1 stat 0 Off 1 On Note1 35 lamp2...

Page 8: ... 45 color space 0 Native 1 Reserve EBU 2 Reserve SMPTE 3 Custom Note2 46 Lens center execute Note1 47 h keystone 350 350 Note1 Note15 48 v keystone 200 200 Note1 Note15 49 warp rotat 20 20 in unit 50 warp pinbrl 100 100 51 warp tlc x x 192 192 52 warp tlc y y 120 120 53 warp trc x x 192 192 54 warp trc y y 120 120 55 warp blc x x 192 192 56 warp blc y y 120 120 57 warp brc x x 192 192 58 warp brc ...

Page 9: ...eset execute 80 scen adl 0 Off 1 On 81 brilliant blend 0 Off 1 On 82 ir addr 0 remote code 1 1 remote code 2 83 eco net pow 0 Off RJ45 Power On 1 On RJ45 Power Off 84 net ipaddr 85 net subnet 86 net gateway 87 net dhcp 0 Off 1 On 88 menu pos 0 Top left 1 Top right 2 Bottom left 3 Bottom right 4 center Note1 89 startup logo 0 Off 1 On 90 startup chime 0 Off 1 On 91 92 93 94 95 btn 1 btn 2 btn 3 btn...

Page 10: ...0 Off 1 On Note1 99 lang 0 English 1 French 2 Spanish 3 German 4 Portuese 5 Chinese Simplified 6 Chinese Traditional 7 Japanese 8 Korean 9 Russian 100 model 101 ser no 102 sw ver Note13 103 act src 0 HDMI 1 1 HDMI 2 2 VGA 3 YUV 1 4 RGBHV YUV2 5 Reserve 6 Reserve 7 Reserve 8 SDI HDSDI 3G Note1 104 pip src 0 HDMI 1 1 HDMI 2 2 VGA 3 YUV 1 4 RGBHV YUV2 5 Reserve 6 Reserve 7 Reserve 8 SDI HDSDI 3G Note...

Page 11: ...999 Note1 130 picture mute 0 Off 1 On 131 power on execute 132 power off execute 133 text mode 0 Off 1 On 134 status 0 standby 1 warm up 2 imaging 3 cooling 4 warning 135 errcode 0000 FFFF 2 bytes information in hexadecimal format 136 moto ver Note16 REMARK An input command will get back with NA when the input command is Not Applicable in some specific conditions Note1 Not applicable in standby mo...

Page 12: ...en eco net pow is on Note13 Only MCU version number will be read back in standby mode Note14 Not applicable when the internal pattern is displayed Note15 The summation of the absolute value of h keystone and v keystone should not be greater than 350 Note16 The comment is for Motor Software check 1 5 Appendix 1 5 1 Pip main source availability 1 5 2 Input Format 640x480_75Hz_VGA 640x480_85Hz_VGA 80...

Reviews: