![Barco R9010010 Owner'S Manual Download Page 32](http://html1.mh-extra.com/html/barco/r9010010/r9010010_owners-manual_4236021032.webp)
4. Connections
Lamp run time indication while running
When the total run time of the lamp is 30 hours less then 1000 , the following warning message will be displayed for 1 minute. This
warning message will be repeated every 30 minutes. Press
EXIT
to remove the message before the minute is over.
Remaining
Lamp run time
20h
Image 4-2
When the total run time of the lamp is 1000 hours or more, the following warning message, with the exact run time is displayed on
the screen.
WARNING
Lamp run time is x hours
operating the lamp longer
than x hours may damage
the projector.
Please replace the lamp
<ENTER> to continue
Menu 4-1
Lamp run time is 1000 hours. Operating the lamp longer than maximum runtime hours may damage the projector. Please replace
the lamp.
When
ENTER
is pressed to go on, the warning will be repeated every 30 min.
The total lifetime of the lamp for a safe operation is 1000 hours max. Do not use it longer. Always replace with a same type of lamp.
Call a BARCO authorized service technician for lamp replacement.
C
AUTION
:
Using a lamp for more than 1000 hours is dangerous as the lamp could explode.
Lamp Light Output Indication
When starting up and the center lumens measurement is lower than 50 % of its initial value, the lamp light output warning will be
displayed. Press
ENTER
to continue. The message will not be repeated during operation.
WARNING
Lamp run time is X hours
The light output of the lamp
is less
than 50% of its initial value.
It is advisable to replace the
lamp
before damage occurs.
<ENTER> to confirm
Menu 4-2
When the ’Constant Light Output’ (CLO) options is installed, the light output message will appear on the screen when the light output
is reduced with 33% from its initial value.
This message will be repeated every hour.
Lamp Z-axis indication
When starting up and the run time is 100 hours or 250 hours a Z-axis warning will be displayed. This warning will advise to adjust the
Z-axis of the lamp to obtain maximum light output. Press
ENTER
to continue. The message will not be repeated during operation.
WARNING
Lamp run time is X hours.
It is advisable to
adjust the Z-axis
of the lamp to
obtain maximum
light output
(see owner’s manual)
<ENTER> to confirm
Menu 4-3
28
R5976563 BARCOR10 SLM 20/10/2004
Summary of Contents for R9010010
Page 1: ...BarcoR10 SLM Owners Manual R9010010 R5976563 03 20 10 2004...
Page 4: ......
Page 9: ...2 Packaging and Dimensions Image 2 3 Side view dimensions R5976563 BARCOR10 SLM 20 10 2004 5...
Page 10: ...2 Packaging and Dimensions 6 R5976563 BARCOR10 SLM 20 10 2004...
Page 30: ...3 Installation Guidelines 26 R5976563 BARCOR10 SLM 20 10 2004...
Page 88: ...7 Random Access Adjustment Mode 84 R5976563 BARCOR10 SLM 20 10 2004...
Page 120: ...10 Programmable Function Keys 116 R5976563 BARCOR10 SLM 20 10 2004...
Page 124: ...11 Standard Source set up Files 120 R5976563 BARCOR10 SLM 20 10 2004...
Page 132: ...Glossary 128 R5976563 BARCOR10 SLM 20 10 2004...
Page 135: ...Index T Temperature 7 Ambient 7 Z Z axis adjustment 16 R5976563 BARCOR10 SLM 20 10 2004 131...