3. Installation Guidelines
Suggestion
Lamp runtime is
105 hours
It is advisable to
adjust the Z-axis
of the lamp to
obtain maximum
light output
(see owners manual)
<ENTER> to confirm
Menu 3-1
The user can now adjust the Z-axis by following the next procedure.
How to readjust.
1. On the side of the inputs, turn the retaining bolt a quarter counter clockwise.
2. Flip the cover to the left side and take off. (image 3-15)
3. Start up the adjustment mode and select
Service
. (menu 3-2)
4. Select Lamp. The Z-axis indication (lamp menu in service mode) will be helpful while turning screw B . (menu 3-3)
5. Loosen the nut A (image 3-16)on the back of the lamp casing (nutdriver 10).
6. Adjust the screw B (image 3-16)with an Allen key by turning a little clockwise until the maximum light output is reached (the
maximum value of the Z-AXIS indication on the lamp menu).
7. Fasten the nut on the back of the lamp casing to secure this position (nutdriver 10).
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 3-2
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
DIMMING
MORE...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 3-3
LAMP
Constant Light output [OFF]
Using [RS port]
Mode [NORMAL]
Serial number :
R101111
Article number :
R9840xxx
Run time :
10 hours
Remaining run time :
490
hours
Number of strikes :
10
Z_AXIS : 100
Select with
↑
or
↓
then <ENTER>
<EXIT> to return.
Menu 3-4
Image 3-15
Lamp adjustment access
R5976563 BARCOR10 SLM 20/10/2004
17
Summary of Contents for R9010010
Page 1: ...BarcoR10 SLM Owners Manual R9010010 R5976563 03 20 10 2004...
Page 4: ......
Page 9: ...2 Packaging and Dimensions Image 2 3 Side view dimensions R5976563 BARCOR10 SLM 20 10 2004 5...
Page 10: ...2 Packaging and Dimensions 6 R5976563 BARCOR10 SLM 20 10 2004...
Page 30: ...3 Installation Guidelines 26 R5976563 BARCOR10 SLM 20 10 2004...
Page 88: ...7 Random Access Adjustment Mode 84 R5976563 BARCOR10 SLM 20 10 2004...
Page 120: ...10 Programmable Function Keys 116 R5976563 BARCOR10 SLM 20 10 2004...
Page 124: ...11 Standard Source set up Files 120 R5976563 BARCOR10 SLM 20 10 2004...
Page 132: ...Glossary 128 R5976563 BARCOR10 SLM 20 10 2004...
Page 135: ...Index T Temperature 7 Ambient 7 Z Z axis adjustment 16 R5976563 BARCOR10 SLM 20 10 2004 131...