Installation Adjustments
7-3
5976067 BARCOCINE 7 151299
Scheimpfug adjustment
Range of the scheimpfug adjustment
The scheimpfug correction can be adjusted separately for the three tubes within 3 ranges:
range 1 : 1.4 m (55") to 1.9 m (75"), optimum screen width 1.4 m
(55")
range 2 : 1.9 m (75") to 3.2 m (126"), optimum screen width 2.4 m
(94")
range 3 : 3.2 m (126") to 6 m (236"), optimum screen width 4 m
(157")
A correct scheimpfug setting gives the possibility to focus the lenses for a sharp image in all screen areas.
To change the setting from one range to another, some mechanical actions have to done.
range 1
min. SW : 1.40 m (55")
max. SW : 1.90 m (75")
P
P
P
P
P
P
range 2
min. SW : 1.90 m (75")
max. SW : 3.20 m (126")
range 3
min. SW : 3.20 m (126")
max. SW : 6.00 m (236")
Set up of the scheimpfug range
1. Open the top cover (see Installation Guidelines)
2. Loosen the lens bolts (do not remove them), and slide the lens to the front until the scheimflug ring can move freely (nutdriver
11 mm or screwdriver) (image 1).
See installation instructions before
connecting to the supply
V NOM 120/230 Volt
I MAX 5/2.5 AMP
FREQ 60/50 Hz
OFF
ON
/HQVEROWV
*UHHQOHQV
/HQVEROWV
5HGOHQV
/HQVEROWV
%OXHOHQV
image 1
Summary of Contents for R9002380
Page 1: ...INSTALLATION MANUAL Cin 7 R9002380 R9002381 R9002382 R9002387 R9002388 R9002389...
Page 2: ......
Page 12: ...Packaging and Dimensions 2 2 5976067 BARCOCINE 7 151299 Projectordimensions mm...
Page 20: ...InstallationGuidelines 3 8 5976067 BARCOCINE 7 151299...
Page 34: ...Installation Adjustments 6 10 5976067 BARCOCINE 7 151299...
Page 37: ......