Location and Functions of Control
2-1
5976283 BARCOGRAPHICS 808s 160403
2
LOCATION AND FUNCTION OF CONTROLS
REAR PANEL TERMINOLOGY
1
AC Power Switch :
to switch on the projector.
Depending on the set-up of the projector during installation, the projector switches to standby or to 'Operational mode. If in standby,
the standby LED lights up.
2
AC Power Input :
connect the supplied AC power (mains) cord here and to the wall outlet.
3
Communication Port
(800 peripherals)
* Allows communication between the RCVDS switcher and the projector.
* Allows connection of a remote IR receiver unit to the projector.
4
Port 3
RGB Analog Input (9 pin female sub D connector). Allows a character generator, microcomputer, etc. having analog RGB outputs
to be connected to the projector.
5
Port 4/5 : RGB-S Input (5x BNC connector)
:
RGB-S input
: allows a character generator, microcomputer, video camera, etc. having analog RGB output to be connected to the
projector.
Line inputs: - Signals RED-GREEN-BLUE
- COMPOSITE sync. signal
- Tri level sync signal (option)
6
DEFOCUS
: For future expansion
7
75 ohm Termination Switch for S- Video signals
8
X-POS / Y-POS
: For future expansion
9
75 ohm Termination Switch forVideo signals
10
IR Remote
Connector for remote input for hard wired remote control
11
Projector Pilot Lamp
: Indicates the status of the projector.
- Unlit : mains (power) switch is not pressed.
- Lit : mains (power) switch is pressed and the indicated color shows the projector mode:
Green color : operational mode of the projector.
Red color : standby mode of the projector.
Important : projector ("Operational" or "Standby") mode is defined during the installation of the projector. (Refer to a qualified
technician for change).
12
IR Sensor
Receiver for control signals transmitted from the RCU.
13
RS 232 Output Port
RS 232 Input Port allows a communication link for PC or MAC to the next projector in a series of projector.
14
RS 232 Input Port
Connection between the projector and an IBM PC (or compatible) or MAC (RS422) for remote computer control and data communication.
ON
OFF
P O W E R / MAIN S
800 peripherals
R
G
B
Comp-/H-SyncV-Sync
C O MM. P O R T
P O R T 3
PORT 4/5
V-nom
I-nom
Freq
See installation instructions before connecting to the supply.
Voir la notice d’installation avant de raccorder au rØseau.
120/230 V
7/5 Amp
50/60 Hz
DEFOCUS
OFF - ON
75 Ohm
X-POS
Y-POS
green : operation
red : standby
PORT 2
P O R T 1
OFF - ON
75 Ohm
PROJ ECT OR MODE
1
2
3
4
5
7
6
8
9
10
This dev ice complies with part 15 of
the FCC rules. Operation is subj ect to
f o l l o w i n g t w o c o n d i t i o n s ( 1 ) . T h i s
dev ice may not cause harmful inter-
ference, and (2) this dev ice must
accept any interference receiv ed
including interference that may cause
undesired operation"