background image

Date: 06/02/98

R9000901
R9000908

GRAPHICS

Replacement of a picture tube

12

808S

Mounting the units
on the neck of the
picture tube

The Units on the picture tube are clamped on the neck by means of a gear clamp.
Follow the next steps to install:

Gear clamp

Video Drive

support

Gear clamp

Focus Unit

Gear clamp

Deflection Unit

Gear clamp

Video Drive

support

Clasp ring

Focus Unit

Step

Action

1

Slide the two units 

Focus and Deflection unit,

(joined by the ground wire) together on the neck
of the CRT , the  Deflection block fully against
the CRT bulb and the Focus unit ±8 mm from de
Deflection unit (see photo).

2

Tighten slightly the gear clamp of the 

Focus

and Deflection unit 

and the clasp ring of the

Focus unit 

(rotation must be possible for

correct adjustment of the units)

.

3

Slide the 

Video Drive support

 on the end of

the CRT.

4

Tighten not too fast the gear clamp of the 

Video

Drive support 

(position determined when the

Video Driver module is plugged on the CRT).

5

Slide the 

Magnetic unit on

 the end of the CRT

(min 2 cm from the end of the CRT neck).

6

Tighten not too fast the gear clamp of the

Magnetic unit 

(position can change when

adjusting the Magnetic unit).

Summary of Contents for R9000901

Page 1: ...l The following parts of the projector have to be removed to gain access to the picture tubes topcover totalremoval top cover plate covering the picture tube assembly How to open top cover To open the...

Page 2: ...er To remove the top cover proceed to the following step Step Action 1 Stand behind the projector 2 Grip the top cover by the front and turn it until it stands vertical 3 Hit the bottom of the cover o...

Page 3: ...w to remove the metallic cover The metallic cover consists of two parts a fixed plate secured in position by 6 screws and a hinged cover pivoting on the fixed part and locked on the main frame by 4 sc...

Page 4: ...tallic plate To remove the cover assembly continue with the following steps Step Action 1 Remove the 6 screws nut driver 7mm securing the CRT blocks on the plate 2 Remove on both sides of the frame th...

Page 5: ...ctive picture tube Lens How to remove the lens Necessarytool Pot nut runner of 8 mm Support the lens body by hand and remove the 4 screws holding lens to frame The lens is fixed to the main frame by 4...

Page 6: ...ytool Screwdriver5mm The following units have to be disconnected from the main frame deflection unit connection focus unit connection groundconnection videodriverunit EHT lead How to disconnect the pi...

Page 7: ...ection connector 1 2 Removing the picture tube from its frame How to disconnect the EHT lead of the CRT Disconnect the EHT lead as described below Step Action 1 Pull out on the EHT splitter the respec...

Page 8: ...ve the picture tube unit me chanical out of the main frame To remove the picture tube unit out of main frame proceed as follows Step Action 1 Remove the two rods with screwed thread at the end 2 Take...

Page 9: ...e installed Removing the Picture Tube Unit from its support Necessarytool Pot nut runner of 8 mm How to remove the picture tube from its support The CRT Unit is mounted on its support by means of four...

Page 10: ...ve support Gear clamp Focus Unit Gear clamp Deflection Unit Gear clamp Magnetic unit Clasp ring Focus Unit Step Action 1 Loosen the gear clamp of the Magnetic unit 2 Slide the unit off of the end of t...

Page 11: ...k Necessarytool Philips screwdriver to pull tight the gear clamps Order of installation 1 2 3 The CRT Unit is mounted on its support by means of four bolts To mount the CRT unit on its support proceed...

Page 12: ...the neck of the CRT the Deflection block fully against the CRT bulb and the Focus unit 8 mm from de Deflectionunit seephoto 2 Tighten slightly the gear clamp of theFocus and Deflection unit and the cl...

Page 13: ...Picture tube alignment proceed to a quick optical and electrical focus all picture tubes replaced apply an external crosshatch pattern at 15 kHz or use the internal crosshatch rotate the deflection y...

Page 14: ...hing Hor Amplitude in this manual for the alignment of the image width coils Note when only one tube has been replaced the image width of one of the other tubes as a reference and obviously limit thea...