background image

1. PMP replacement Kit

1.3 Blockschematic overview

Overview

PMP = R763067 ?

Actual Soft  =  V1.xx

?

Actual Soft =  V2.02  ?

PMP needs to be

Replaced by

R763864 ?

Replace PMP by

R763864  in the

field

Upgrade Default

program

Br65.3.01_def.bin

 SW = ON

Reboot projector

(Power switch)

Upgrade standard

software

Br65.3.01.bin

Run

CGU652PW.exe

Result  :

3 level uniformity corrections 

:

1  inactive  ( full white

2 identical ( grey levels  for 6500 and PW))

PMP = R763864 ?

END

YES

NO

YES

NO

YES

Projector  up to date

YES

NO

NO

Contact Barco

Need to Upgrade

from  V1.xx  to  V2.02

in the field ?

NO

 SW = OFF

YES

Send projector to

Barco for PMP

replacement and

upgrade

YES

Result  :

3 level uniformity corrections :

all active  2 grey levels

 (for t = 6500°

and PW) and  Full white  at t =6500°)

Result  :

3 level uniformity corrections :

all active  2 grey levels

 (for t = 6500°

and PW) and  Full white  at t =6500°)

Send projector to

Barco for upgrade

and re-alignment

Upgrade Default

program

Reboot projector

(Power switch)

Upgrade standard

software

YES

 SW = ON

STEP 1

STEP 3

STEP 4

There is no real need for an

upgrade from V1.xx to

V2.02 except if the projector

is re- aligned (taking

advantage of the 3 level

uniformity correction)

STEP 2 

Image 1-1

1.4 Extra info

The CGU652PW program

The program does two things:

1.

Initialization of the full white settings in 6500K

2.

Re-use the 1-level grey uniformity corrections for 6500K and copy to the Projector White- grey table.

This program does not improve the uniformity !

R5976881 R6000 SERIES PMP 15/03/2005

3

Summary of Contents for R6300

Page 1: ...R6000 series PMP Installation Manual R763864K R5976881 00 15 03 2005 ...

Page 2: ...Barco nv Presentations Noordlaan 5 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 35 86 51 E mail presentations bid barco com Visit us at the web www barco com Printed in Belgium ...

Page 3: ...ws 6500 K 2 levels grey full white Projector White 1 level grey Software version Characterisitcs V1 12 Std version R6300 V3 01 for new PMP 3 level unif V1 12 Std version R6400 V3 01 for new PMP 3 level unif V1 12 Std version V2 02 3 level unif R6400i V3 01 for new PMP 3 level unif V1 12 Std version V2 02 3 level unif R6500 V3 01 for new PMP 3 level unif V1 xx to V2 02 Upgrade In the new soft V2 02...

Page 4: ...nd on the existing software in the projector If the software in the projector is lower than V2 02 you have to upgrade to V3 01 and this will necessitate all 4 steps as described hereafter In case you have to change from a 1 level version to a 3 level uniformity version you can decide to return the projector to the factory for an upgrade including the 3 level uniformity adjustment If however you de...

Page 5: ...l uniformity corrections all active 2 grey levels for t 6500 and PW and Full white at t 6500 Result 3 level uniformity corrections all active 2 grey levels for t 6500 and PW and Full white at t 6500 Send projector to Barco for upgrade and re alignment Upgrade Default program Reboot projector Power switch Upgrade standard software YES SW ON STEP 1 STEP 3 STEP 4 There is no real need for an upgrade ...

Page 6: ...you overwrite the factory set 3 level corrections The final result is a worse uniformity Summary If case of doubts please contact Barco before starting the upgrade Check the soft of the projector before you start the CGU625PW exe program When the projector was upgraded with the above special uniformity program to e g V2 02 it is not possible to differentiate it from a factory adjusted 3 level V2 0...

Page 7: ...Index INDEX D description 1 E Extra info 3 I Introduction 1 O overview 3 U upgrade 2 R5976881 R6000 SERIES PMP 15 03 2005 5 ...

Reviews: