1. Safety & Environmental Information

Keep

fl

ammable materials away from the installation (such as curtains). A lot of energy is transferred into heat. The installation

should be such that the amount of air

fl

ow required for safe operation of the equipment is not compromised. Proper ventilation must

be provided.

ESD and LEDs:

LED components used in R-Series LED sheets are ESD (Electro-Static Discharge) sensitive. To prevent the possibility of destroying
LED components do not touch either in operation or while switched off.

Risk of electric shock / Risk of

fi

re:

To protect against risk of

fi

re caused by overloading of power cables, each power source cable should be protected by a type D

circuit breaker rated 16 A / 250 VAC (20 A / 250 VAC in the USA and Canada).

For the 200–240 VAC range up to three PSUs can be connected to one circuit at the same time. For the 100–130 VAC range up to
two PSUs can be connected to one circuit at the same time.

Disconnect device:

The socket outlets supplying one or more R-Series products shall be installed near the equipment and be easily accessible, or a
readily accessible general disconnect device must be incorporated in the

fi

xed wiring.

Unplug / disconnect all mains input connections to remove all power from the R-Series products.

The disconnect device shall simultaneously interrupt all poles of the AC mains supply, except for the earthing conductor. This shall
be installed near the equipment and be easily accessible.

This equipment MUST be earthed:

In order to protect against risk of electric shock, the installation should be properly grounded according to local regulations. Defeating
the purpose of the grounding type plug will expose you to the risk of electric shock.

Power system:

It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and Ground Fault
Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special attention
should be given to HD 60364, Harmonization Document for electrical installation of buildings. In Germany VDE 0100 should be
adhered to. In America, special attention should be given to the National Electrical Code, ANSI/NFPA 70.

Data cables:

The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cables are
damaged, replace them only with new ones. Never try to repair a data cable. Per requirements of the National Electrical Code® in
the USA , the length of a data cable must not exceed 100 m (328 feet). Avoid exposure of data cables to accidental contact with
lightning or power conductors.

Only use data cables provided by Barco. The diameter of the cables provided by Barco is chosen to

fi

t the connection box. Only

these cables can guarantee the water tightness of the system.

Mains cords:

The power cords delivered with this system have special properties for safety; they are not user serviceable. If the power cords are
damaged, replace them only with new ones. Never try to repair a power cord.

LEDs:

The LEDs used on the R-series sheets are fragile. Never push with a hard or sharp object onto the lens of the LED as this may
cause damage to the LED. The maximum allowed load upon the lens of the LED is 300 gram/LED, but only a force perpendicular to
the screen surface is allowed. Be careful when installing a shader upon the R-series sheet. Shaders

fi

t in one of two directions and

the orientation should be veri

fi

ed before pushing into

fi

nal position. Use your bare

fi

ngers (not nails) to press the shader over the

LEDs. Use your

fi

nger nails to press upon the framework of the shader between the LEDs (not upon the LEDs) to push the shader

in its

fi

nal position.

Do not hot plug:

Do not hot plug any cables. Damage to the connector pins may occur. Resulting damage is not covered under warranty.

Base surface:

The R-Series LED sheets cannot be directly installed on the wall.

An electrically grounded aluminium back plate must be

installed between that wall and the LED sheets.

To ensure a correct thermal expansion (CTE) and electromagnetic compatibility (EMC), Barco provides a solution with Reynobond®
panels, a speci

fi

c foam tape and various installation brackets. These optional parts are added externally to the certi

fi

ed R-series

product.

When not using this Barco veri

fi

ed solution the following needs to be taken into account:

Only install base surfaces consisting of noncombustible material or self-extinguishing material.

Make sure the LED sheets are not accessible for non-quali

fi

ed personnel.

Make sure to provide suf

fi

cient extra mechanical safeties (e.g. safety cables) according to local regulations.

Loosening

4

R5906040 R-SERIES 16/02/2017

Summary of Contents for R Series

Page 1: ...R Series Safety Environmental Information R5906040 02 16 02 2017 ...

Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco com en support Visit us at the web www barco com Printed in Belgium ...

Page 3: ...isible LED area of 26 or 52 cm wide and maximum 468 cm long An LED sheet also contains 1 2 termination box es and 1 2 connection box es depending on the width of the LED sheet An LED sheet of 26 cm wide has 1 of both termination and connection box an LED sheet of 52 cm wide has 2 of both termination and connection boxes Because of the variable length and width of a LED sheet it can contain from 1 ...

Page 4: ...d and TRAINED PERSONNEL only For installation sites who are unable to provide sufficient trained personnel Barco can provide a variant of the R Series products which can be installed by INFORMED PERSONNEL as well Accredited SAFETY OFFICERS must ensure the safety of the site construction assembly connection use dismantling transport etc of safety critical systems Notice on safety This equipment is ...

Page 5: ...inched Only use attachments accessories specified by the manufacturer Disconnect the power to this apparatus during lightning storms or provide suitable additional lightning protection Unplug this apparatus when unused for long period of time Refer all servicing to qualified service technicians personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord...

Page 6: ...ered to In America special attention should be given to the National Electrical Code ANSI NFPA 70 Data cables The data cables provided with this system have special properties for safety They are not user serviceable If the data cables are damaged replace them only with new ones Never try to repair a data cable Per requirements of the National Electrical Code in the USA the length of a data cable ...

Page 7: ... stored in an R series wooden crate large sizes or card board box smaller sizes may only be placed horizontally upon flat surfaces free of clutter No force can be applied to the LEDs Any LEDs damaged due to mechanical stress are not covered by the warranty Safety and functional features of the screen may not be defeated Nothing is allowed to hang from the cables of an R series product Any failures...

Page 8: ...section Limit Requirements of toxic substances in Electronic Information Products 零件项目 名称 Component name 有毒有害物质或元素 Hazardous substances and elements 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr6 多溴联苯 PBB 多溴二苯醚 PBDE 印制电路配件 Printed Circuit Assemblies x O O O O O 外接电 线 缆 External Cables x O O O O O 电源供应器 Power Supply Unit x O O O O O 塑胶外壳 Metal Enclosure O O O O O O 塑胶外壳 Plastic Enclosure O O O O O O 螺帽 螺钉 栓 螺旋 钉 垫圈 紧固件 Nu...

Page 9: ... 10 Turkey RoHS compliance Türkiye Cumhuriyeti AEEE Yönetmeliğine Uygundur Republic of Turkey In conformity with the WEEE Regulation 1 7 Production address Factory Barco NV Noordlaan 5 8520 Kuurne BELGIUM R5906040 R SERIES 16 02 2017 7 ...

Reviews: