background image

BARCO ——————————————————— 1

————————————— Projection Systems

To be continued on next page.

QGD(7:1) Lens R9840030

What has to be

done

This new lens has to be installed on a 6000 serie projector

Necessary Tools

no tool necessary

Installing the

Lens

To install the lensholder adapter, follow the next procedure :

1

2

3

4

5

6

7

1

1

2

2

Open the lens cover of the projector.

Pivote the motor part up.

Open both lens locks by pulling them backwards.

Put the lens and the lens holder with the rounded part

down.

Fix the lens by closing the both locks (A) until they are

secured.

Pivote the motor part (B) down and turn the switch trough

the gap in the motor part 90° (see image 1).

Re-install the lens cover.

Step

Action

Image

Illustration

Lens lockings

Image 1

Image 2

Switch

Summary of Contents for QGD(7:1) R9840030

Page 1: ...BARCO PROJECTION SYSTEMS Date 060799 INSTALLATION MANUAL LENS QGD 7 1 FOR 6000 SERIES R9840030 Art No R5976019 Rev 1 QGD 7 1 Kit ...

Page 2: ...ice Produced by BARCO NV July 1999 All rights reserved Trademarks are the rights of their respective owners BARCOn v ProjectionSystems Noordlaan5 B 8520Kuurne Belgium Tel 32 56 368211 Fax 32 56 351651 E mail sales bps barco com Visite Barco at the web http www barco com Printed in Belgium ...

Page 3: ...ext procedure 1 2 3 4 5 6 7 1 1 2 2 Open the lens cover of the projector Pivote the motor part up Open both lens locks by pulling them backwards Put the lens and the lens holder with the rounded part down Fix the lens by closing the both locks A until they are secured Pivote the motor part B down and turn the switch trough the gap in the motor part 90 see image 1 Re install the lens cover Step Act...

Page 4: ... in meter PD 6 853 x SW 0 047 0 0095 SW Inch system PD and SW in inch PD 6 853 x SW 1 85 14 72 SW BarcoReality 6300 Metric system PD and SW in meter PD 7 021 x SW 0 047 0 0093 SW Inch system PD and SW in inch PD 7 021 x SW 1 85 14 41 SW Adjusting the Lens To adjust the lens follow the next procedure 1 2 1 1 Adjust the lens A until the image is focused Secure this lens position with the locking rin...

Page 5: ...Always wipe lenses with a CLEAN TorayseeTM cloth Always wipe lenses in a single direction Do not wipe back and for wards across the lens surface as this tends to grind dirt into the coating Do not leave cleaning cloth in either an open room or lab coat pocket as doing so can contaminate the cloth If smears occur when cleaning lenses replace the cloth Smears are the first indication of a dirty clot...