Power cords

Europe: H05VV-F or H05VVH2-F PVC cord with appropriate EU plug.
US and Canada:

hospital grade

cord-set has to be used, provided with instructions to indicate that

grounding reliability can be achieved only when the equipment is connected to an equivalent receptacle
marked hospital only or hospital grade. These instructions need to be marked either on the equip. or on a
tag on the power cord

Do not overload wall outlets and extension cords as this may result in fire or electric shock.

Mains lead protection: Power cords should be routed so that they are not likely to be walked upon or
pinched by items placed upon or against them, paying particular attention to cords at plugs and
receptacles.

The power supply cord shall only be replaced by the designated operator.

Use a power cord that matches the voltage of the power outlet, which has been approved and complies
with the safety standard of your particular country.

Water and moisture

Never expose the display to rain or moisture.

Never use the display near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or
in a wet basement.

Moisture condensation

Do not use monitor under rapid temperature and humidity change condition or avoid cold air from air-
conditioning outlet directly.

Moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection
plate, this is not a malfunction of the product itself, although it may cause damage to the monitor.

If condensation appears, let the monitor stand unplugged until the condensation disappears.

Ventilation

Do not cover or block any ventilation openings in the cover of the set. When installing the device in a cupboard
or another enclosed location, heed the necessary space between the set and the sides of the cupboard.

Installation

Place the device on a flat, solid and stable surface that can support the weight of at least 3 devices. If you use
an unstable cart or stand, the device may fall, causing serious injury to a child or adult, and serious damage to
the device.

National Scandinavian Deviations for CL. 1.7.2

Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"

Norway: "Apparatet må tilkoples jordet stikkontakt"

Sweden: "Apparaten skall anslutas till jordat uttag"

5.2 Environmental information

Disposal Information

Waste Electrical and Electronic Equipment

This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste

from electrical and electronic equipment, this product must not be disposed of with other municipal waste.
Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of
waste electrical and electronic equipment. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.

Important information

Summary of Contents for Nio Color 2 MP

Page 1: ...ENABLING BRIGHT OUTCOMES MDNC 2123 option DE User Guide Nio Color 2MP 23...

Page 2: ...Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Page 3: ...lection 17 3 6 Luminance adjustment 17 3 7 sRGB color space 17 3 8 Display functions 18 3 9 White point selection 18 3 10 Power save mode 19 3 11 OSD menu language 19 3 12 Factory reset 19 4 Maintenan...

Page 4: ...K5902134 04 Nio Color 2MP 23 4...

Page 5: ...is always up to standard because of Barco s luminance sensor technology and MediCal QAWeb software By constantly measuring and monitoring display brightness we can ensure that your dental images will...

Page 6: ...K5902134 04 Nio Color 2MP 23 6 Gives additional information about the described subject Gives extra advice about the described subject Welcome...

Page 7: ...f operation Keep your original packaging It is designed for this display and is the ideal protection during transport and storage 1 2 Product overview Front 1 2 3 4 5 6 Image 1 1 1 Stand base plate 2...

Page 8: ...ion mode or display is not powered Blinking orange Display is entering standby mode Steady orange Display is in standby mode Back 8 1 2 3 4 6 7 5 Image 1 2 1 Kensington security slot 2 USB B 2 0 upstr...

Page 9: ...Sufficient expertise is required to install this equipment All devices and complete setup must be tested before taking into operation CAUTION When the display is assembled in the medical system take...

Page 10: ...ar 90 counterclockwise Image 2 1 3 Attach the stand base plate to the pillar by fixing the dedicated screw as shown below Image 2 2 2 2 Cable connections To connect the cables 1 Connect one or more vi...

Page 11: ...mage 2 4 3 Connect the mains power input to a grounded power outlet Image 2 5 4 If necessary for your application earth the Nio Color 2MP 23 by connecting the earth pin to a grounded outlet by means o...

Page 12: ...CAUTION Although the display can be physically rotated to portrait position this mode is functionally not supported 2 4 VESA mount installation To mount the display on a VESA arm The display panel sta...

Page 13: ...Color 2MP 23 13 2 Use 4 M4 screws to attach the panel to a VESA approved arm Please respect the following rule to select an appropriate screw length Lmin T W 6 mm Lmax T W 14 mm T W Lmin Lmax Image 2...

Page 14: ...K5902134 04 Nio Color 2MP 23 14 Installation...

Page 15: ...15 K5902134 04 Nio Color 2MP 23 Operation 3...

Page 16: ...c elements Understand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or perm...

Page 17: ...seconds until the OSD unlocked message appears 3 5 Input source selection About input source selection The Nio Color 2MP 23 can have multiple video inputs connected Switching between the different in...

Page 18: ...unction for most medical viewing applications The DICOM display function applies ambient light compensation ALC taking the ambient light conditions of your reading room into account The available read...

Page 19: ...o enable disable power save mode 1 Bring up the OSD main menu 2 Navigate to the Adjustments Settings menu 3 Enter the Power save submenu 4 Select On or Off as desired and confirm 3 11 OSD menu languag...

Page 20: ...K5902134 04 Nio Color 2MP 23 20 Operation...

Page 21: ...21 K5902134 04 Nio Color 2MP 23 Maintenance 4...

Page 22: ...excess liquid may cause damage to internal electronics Instead apply the liquid to a cleaning cloth To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistene...

Page 23: ...23 K5902134 04 Nio Color 2MP 23 Important information 5...

Page 24: ...ent is unlikely no applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patie...

Page 25: ...ction plate this is not a malfunction of the product itself although it may cause damage to the monitor If condensation appears let the monitor stand unplugged until the condensation disappears Ventil...

Page 26: ...lectronic Products Also called RoHS of Chinese Mainland the table below lists the names and contents of toxic and or hazardous substances that Barco s product may contain The RoHS of Chinese Mainland...

Page 27: ...pe and clean and therefore suitable to be used for various applications in hospitals and other medical environments where procedures for frequent cleaning are specified However normal use shall exclud...

Page 28: ...ng antenna Increase the separation between the device and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experi...

Page 29: ...relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is c...

Page 30: ...l commercial or hospital environment Conducted RF IEC 61000 4 6 3 Vrms 6 Vrms in ISM bands 150 kHz to 80 MHz 3 Vrms 6 Vrms in ISM bands Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 7 GHz 3 V m Immunity...

Page 31: ...ons Indicates the device is approved according to the UL regulations for Canada and US E352529 Indicates the device is approved according to the UL regulations for Canada and US Indicates the device i...

Page 32: ...e device to safely operate within specs SN Indicates the device serial number REF Indicates the device part number or catalogue number Warning dangerous voltage Caution Consult the operating instructi...

Page 33: ...e can be safely exposed when being stored 5 7 Legal disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document we assume no responsibility for err...

Page 34: ...ient light presets Yes reading room selection Ambient light sensor Yes Front sensor Yes Maximum luminance panel typical 460 cd m DICOM calibrated luminance 370 cd m Contrast ratio panel typical 1000 1...

Page 35: ...class IIb product CCC China Safety specific IEC 60950 1 2005 A1 2009 EN 60950 1 2006 A1 2010 A11 2009 A12 2011 A2 2013 IEC 60601 1 2005 A1 2012 EN 60601 1 2006 A1 2013 A12 2014 ANSI AAMI ES 60601 1 2...

Page 36: ...olor 2MP 23 36 Storage temperature 20 C to 60 C Operating humidity 8 to 80 non condensing Storage humidity 5 to 85 non condensing Operating pressure 70 kPa minimum Storage pressure 50 to 106 kPa Impor...

Page 37: ...K5902134 04 Nio Color 2MP 23 37 Important information...

Page 38: ...V Beneluxpark 21 8500 Kortrijk Belgium Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com K5902134 04 2018 11 07 Barco NV President Kennedypark 35 8500 Kortrijk B...

Reviews: