41
K5903058 /11
Nio 2MP LED Display
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna or equipment.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The Nio 2MP LED Display is intended for use in the electromagnetic environment specified below. The
customer or the user of the Nio 2MP LED Display should assure that it is used in such an environment.
Immunity test
IEC 60601-1-2 test levels Compliance level
Electromagnetic
environment
–
guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15
kV air
Floors should be wood,
concrete or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should be
at least 30%
Electrical fast transient/
burst
IEC 61000-4-4
± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency
± 2 kV for power supply
lines
± 1 kV for input/ output
lines
100 kHz repetition
frequency
Mains power quality
should be that of a typical
commercial or hospital
environment
Surge
IEC61000-4-5
Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV
Line to line: ± 0.5 kV, ± 1
kV
Line to ground: ± 0.5 kV, ±
1 kV, ± 2 kV
Mains power quality
should be that of a typical
commercial or hospital
environment
Voltage dips, short
interruptions and voltage
variations on power supply
input lines
IEC 61000-4-11
0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°
0% residual voltage for 0.5
period at 0°, 45°, 90°,
135°, 180°, 225°, 270°
and 315°
0% residual voltage for 1
period at 0°
70% residual voltage for
25 periods at 0°
Voltage interruptions: 0%
residual voltage for 250
periods at 0°
Mains power quality
should be that of a typical
commercial or hospital
environment. If the user of
the Nio 2MP LED Display
requires continued
operation during power
mains interruptions, it is
recommended that the Nio
2MP LED Display be
powered from an
uninterruptible power
supply or a battery
Power frequency (50/60
Hz) magnetic field
IEC 61000-4-8
30 A/m
Not applicable
2
Power frequency
magnetic fields should be
at levels characteristic of a
typical location in a typical
commercial or hospital
environment
Conducted RF
IEC 61000-4-6
3 Vrms (6 Vrms in ISM
bands)
150 kHz to 80 MHz
3 Vrms (6 Vrms in ISM
bands)
-
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to 2.7 GHz
3 V/m
2.
Nio 2MP LED Display doesn
’
t contain components that are susceptible to magnetic fields.
Summary of Contents for Nio 2MP LED
Page 1: ...ENABLING BRIGHT OUTCOMES MDNC 2221 User Guide Nio 2MP LED Display...
Page 5: ...5 K5903058 11 Nio 2MP LED Display Welcome 1...
Page 8: ...K5903058 11 Nio 2MP LED Display 8 Welcome...
Page 9: ...9 K5903058 11 Nio 2MP LED Display Installation 2...
Page 16: ...K5903058 11 Nio 2MP LED Display 16 Installation...
Page 17: ...17 K5903058 11 Nio 2MP LED Display Daily operation 3...
Page 20: ...K5903058 11 Nio 2MP LED Display 20 Enter Cancel Standby IEC 60417 5009 Daily operation...
Page 21: ...21 K5903058 11 Nio 2MP LED Display Advanced operation 4...
Page 28: ...K5903058 11 Nio 2MP LED Display 28 Advanced operation...
Page 29: ...29 K5903058 11 Nio 2MP LED Display Maintenance 5...
Page 32: ...K5903058 11 Nio 2MP LED Display 32 Maintenance...
Page 33: ...33 K5903058 11 Nio 2MP LED Display Important information 6...
Page 50: ...K5903058 11 Nio 2MP LED Display 50 Important information...
Page 51: ...51 K5903058 11 Nio 2MP LED Display Troubleshooting 7...
Page 53: ......
Page 54: ...www barco com K5903058 11 2021 12 20 Barco NV President Kennedypark 35 8500 Kortrijk Belgium...