7. Cabling of MiSPHERE control boxes
7.2 Data cabling of MiSPHERE control boxes
Necessary parts
•
Waterproof data linking cables.
•
One dummy data plug.
How to realize the data cabling of MiSPHERE control boxes ?
1. Connect the data cable, coming from the digitizer, with the data input socket of the first control box.
Note:
The maximum cable length between the digitizer and the first control box may not exceed 5 meter.
2. Daisy chain the data-linking cables from the data output socket of previous control box to the data input of the next.
3. Place a dummy data plug on the data output socket of the last control box in the chain.
4. Make sure that all plug holder clamps are locked firmly.
Example of data cabling
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
E
F
D
Image 7-3
D Data cable between digitizer and first control box.
E
Waterproof data linking cable.
F
Dummy data plug.
R5976941 MISPHERE 03/01/2006
39
Summary of Contents for MiSPHERE
Page 1: ...MiSPHERE Installation manual R5976941 00 03 01 2006 ...
Page 4: ......
Page 6: ...Table of contents 2 R5976941 MISPHERE 03 01 2006 ...
Page 12: ...1 Safety 8 R5976941 MISPHERE 03 01 2006 ...
Page 16: ...2 Installation requirements 12 R5976941 MISPHERE 03 01 2006 ...
Page 30: ...4 MiSPHERE peripherals and accessories 26 R5976941 MISPHERE 03 01 2006 ...
Page 34: ...5 Setup process of a MiSPHERE system 30 R5976941 MISPHERE 03 01 2006 ...
Page 44: ...7 Cabling of MiSPHERE control boxes 40 R5976941 MISPHERE 03 01 2006 ...
Page 48: ...8 Maintenance 44 R5976941 MISPHERE 03 01 2006 ...
Page 56: ...B Specifications 52 R5976941 MISPHERE 03 01 2006 ...