3. Components of a MiSPHERE system
3.2 MiSPHERE control box
Introduction MiSPHERE control box
The MiSPHERE control box contains a power supply unit, a distribution interface and a controller/re-sync unit. All together covered
in an rugged IP65 housing. The control box is attached to a mounting plate for easy installation.
A
B
C
D
Image 3-9
A
Fan.
B
Standard outdoor connector ports.
C Power/data output ports.
D Mounting plate.
The power supply requires an input voltage between 200 and 240 volt AC. The distribution interface has 4 output ports to connect a
MiSPHERE string with. The re-sync unit contains the standard Barco LED-wall outdoor connector ports to link the data and power
from tile to tile.
Input/output ports of the MiSPHERE control box
The illustration below shows the different connection ports of the MiSPHERE control box. At the left side of the illustration you can
see the front view of the MiSPHERE control box with the power/data input/output ports used to realize the power and data connec-
tions from control box to control box. At the right side of the illustration below you can see the bottom view of the MiSPHERE control
box with the four power/data output ports where a long interconnection cable can be plugged in leading to the MiSPHEREstring.
1
2
3
4
C
D
B
A
1
3
2
4
Image 3-10
A
Data output port.
B
Data input port.
C Power input socket.
D Power output socket.
1
Power/data output port number 1 (to the first MiSPHERE string).
2
Power/data output port number 2 (to the second MiSPHERE string).
3
Power/data output port number 3 (to the third MiSPHERE string).
4
Power/data output port number 4 (to the fourth MiSPHERE string).
Each output port can place a dedicated color upon the MiSPHERE string. This makes the identification of the MiSPHERE strings
easier.
•
Port 1 : Red
•
Port 2 : Green
•
Port 3 : Blue
•
Port 4 : White
Using an MiSPHERE control box as stand alone re-sync unit
The MiSPHERE control box acts like a stand alone re-sync unit in case no power is applied to the power input socket of the control
box. When you use the MiSPHERE control box as stand alone re-sync unit ensure to place dummy plugs upon the power input and
16
R5976941 MISPHERE 03/01/2006
Summary of Contents for MiSPHERE
Page 1: ...MiSPHERE Installation manual R5976941 00 03 01 2006 ...
Page 4: ......
Page 6: ...Table of contents 2 R5976941 MISPHERE 03 01 2006 ...
Page 12: ...1 Safety 8 R5976941 MISPHERE 03 01 2006 ...
Page 16: ...2 Installation requirements 12 R5976941 MISPHERE 03 01 2006 ...
Page 30: ...4 MiSPHERE peripherals and accessories 26 R5976941 MISPHERE 03 01 2006 ...
Page 34: ...5 Setup process of a MiSPHERE system 30 R5976941 MISPHERE 03 01 2006 ...
Page 44: ...7 Cabling of MiSPHERE control boxes 40 R5976941 MISPHERE 03 01 2006 ...
Page 48: ...8 Maintenance 44 R5976941 MISPHERE 03 01 2006 ...
Page 56: ...B Specifications 52 R5976941 MISPHERE 03 01 2006 ...