background image

ENABLING BRIGHT OUTCOMES

MDNG-6221 (option NC EM)

User Guide

5.8MP high-bright display

Nio 5MP

Summary of Contents for MDNG-6221

Page 1: ...ENABLING BRIGHT OUTCOMES MDNG 6221 option NC EM User Guide 5 8MP high bright display Nio 5MP...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Page 3: ...peration 18 3 2 Key indicator lights 18 3 3 Standby switching 19 3 4 OSD menu access 19 3 5 OSD menu navigation 19 3 6 Viewing mode 20 4 Advanced operation 21 4 1 OSD menu language 22 4 2 OSD menu aut...

Page 4: ...19 Image source selection 30 4 20 Grayscale conversion modes 32 4 21 EDID format 32 4 22 EDID timings 32 4 23 Display info 33 4 24 Display status 33 5 Cleaning your display 35 5 1 Cleaning instructio...

Page 5: ...5 K5902142 04 Nio 5MP Welcome 1...

Page 6: ...edicated user guide is available on the documentation disc Keep your original packaging It is designed for this display and is the ideal protection during transport and storage 1 2 At a glance Front 2...

Page 7: ...23 and Hibernate page 24 7 Ambient light sensor 8 Front sensor Back 9 8 10 11 12 1 2 3 5 6 4 7 CHANNEL 2 CHANNEL 1 Image 1 2 1 24 VDC power input 2 Channel 2 DisplayPort video input 3 Channel 2 DVI vi...

Page 8: ...K5902142 04 Nio 5MP 8 Welcome...

Page 9: ...9 K5902142 04 Nio 5MP Installation 2...

Page 10: ...of your display For more information and installation instructions please check the Barco Display Controller and Intuitive Workflow Tools user guide on the included documentation CD or at www barco c...

Page 11: ...en the result depends on the graphic board and the resolution of the image In some cases the image will be rotated automatically in other cases it will not be rotated e g when pixels would be lost aft...

Page 12: ...HANNEL 1 Image 2 5 3 Connect the workstation s USB host to the USB upstream connector on the display if you want to make use of QAWeb or any of the display USB downstream connectors e g to connect a k...

Page 13: ...Tools are designed to increase visibility of subtle details improve focus during reading sessions and accelerate workflow To install the MXRT driver and Intuitive Workflow Tools 1 Switch on your Nio 5...

Page 14: ...b visit www barco com support medical qaweb to obtain the installation package and user documentation 2 6 VESA mount installation CAUTION Use suitable mounting apparatus to avoid risk of injury WARNIN...

Page 15: ...2 11 4 Slide the plastic cover over the neck of the foot Image 2 12 5 Remove the four screws fixing the foot while supporting the foot Image 2 13 6 Attach the arm stand firmly to the panel using 4 sc...

Page 16: ...K5902142 04 Nio 5MP 16 Installation...

Page 17: ...17 K5902142 04 Nio 5MP Daily operation 3...

Page 18: ...ls As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performance of the product To ensur...

Page 19: ...menu access About the OSD menu The OSD menu allows you to configure different settings to make your Nio 5MP fit your needs within your working environment Also you can retrieve general information ab...

Page 20: ...mately half of the luminance This is intended for using the display with office applications such as word processing Please note that text mode is not persistent Once powered off the display will rest...

Page 21: ...to change and configure them Certain OSD menu settings affecting calibration can be managed by QAWeb Manually changing these settings in the OSD menu is still possible but the changes will be overwrit...

Page 22: ...3 Power LED About the power LED To prevent distractions the power LED is off by default when the display is switched on and used in normal operation This behavior can be changed so that the power LED...

Page 23: ...function 1 Bring up the OSD main menu 2 Navigate to the Configuration User Interface Controls menu 3 Enter the Power Lock submenu 4 Select Enabled Disabled as desired and confirm 4 6 DPMS mode About...

Page 24: ...onfirm To adjust the hibernate time out 1 Bring up the OSD main menu 2 Navigate to the Configuration Power Management menu 3 Enter the Hibernate Timeout submenu 4 Set the time out value as desired and...

Page 25: ...luminance target 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration menu 3 Enter the Luminance Target submenu 4 Set a luminance target value as desired and confirm The default f...

Page 26: ...prove the quality and communication of digital images in radiology In short the DICOM display function results in more visible grayscales in the images Barco recommends selecting the DICOM display fun...

Page 27: ...ach of these reading rooms are defined by following parameters the maximum light allowed in this type of room the preset ambient light correction value for this reading room These parameters are store...

Page 28: ...report About DICOM status report Following information is available DICOM Compliance Status status since last compliance check Compliance status Shows if the current DICOM curve is compliant or not Ma...

Page 29: ...DICOM calibration to start the calibration Warning Pressing a key during calibration will abort the calibration previous values will be restored Note After calibration the compliance check will start...

Page 30: ...idual pixel to one or more adjacent pixels so that the size of the displayed image will be a multiple of the original image source video input signal Image scaling is only possible when the resolution...

Page 31: ...he Configuration Image Sources menu 3 Enter the Image Source Selection submenu and select Automatic To manually select an image source 1 Bring up the OSD main menu 2 Navigate to the Configuration Imag...

Page 32: ...lue channel This mode is intended for grayscale displays where gray is sent over the blue channel To manually select a grayscale conversion mode 1 Bring up the OSD main menu 2 Navigate to the Configur...

Page 33: ...our display 1 Bring up the OSD main menu 2 Navigate to the About this Display menu to make the information visible on the screen 4 24 Display status About display status The Status submenu of the OSD...

Page 34: ...K5902142 04 Nio 5MP 34 Advanced operation...

Page 35: ...35 K5902142 04 Nio 5MP Cleaning your display 5...

Page 36: ...certain cleaning product use plain water Do not use any of the following products Alcohol in concentrations 70 Strong alkalis lye strong solvents Acetone Toluene Acids Detergents containing fluoride D...

Page 37: ...37 K5902142 04 Nio 5MP Important information 6...

Page 38: ...support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with external 24 VDC power...

Page 39: ...qualified service technicians under the following conditions If the power cord or plug is damaged or frayed If liquid has been spilled into the equipment If the equipment has been exposed to rain or w...

Page 40: ...arco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with the WEEE Regulation RoHS Chinese Mainland RoHS RoHS Barco RoHS MCV According to t...

Page 41: ...EFUP logo that Barco uses please refer to the photo is based on the General guidelines of environment friendly use period of electronic information products of Chinese Mainland 10 RoHS China RoHS SDo...

Page 42: ...ccept any interference received including interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part...

Page 43: ...sions CISPR 11 Group 1 The Nio 5MP uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF...

Page 44: ...ge interruptions 0 residual voltage for 250 periods at 0 0 residual voltage for 0 5 period at 0 45 90 135 180 225 270 and 315 0 residual voltage for 1 period at 0 70 residual voltage for 25 periods at...

Page 45: ...3 28 5240 5100 5800 W LAN 802 11 a n Pulse modulation 217 Hz 0 2 0 3 9 5500 5785 6 6 Explanation of symbols Symbols on the device On the device or power supply you may find the following symbols nonre...

Page 46: ...ates the device is approved according to the RCM regulations Indicates the device is approved according to the EAC regulations Caution Federal law United Stated of America restricts this device to sal...

Page 47: ...epresentative for the European Union REP CH Indicates the Authorised Representative for Switzerland Warning dangerous voltage Caution Consult the Instructions For Use eIFU indicator Consult the Instru...

Page 48: ...should be carried with two persons Indicates that the box should not be cut with a knife a cutter or any other sharp object 20 C 60 C xx yy Indicates the temperature limits5 to which the device can be...

Page 49: ...rity Incident Response As a global technology leader Barco is committed to deliver secure solutions and services to our customers while protecting Barco s intellectual property When product security c...

Page 50: ...marked on the medical power supply Input rating 100 240 VAC 3 0 A 50 60 Hz Output rating 24 VDC 8 33 A 5 VDC 0 1 A Power consumption 60 W nominal 0 5 W standby Dimensions with stand W x H x D Portrait...

Page 51: ...WEEE Packaging Directive Supplied accessories User guide Documentation disc System sheet Video cable 1 x DisplayPort Mains cable s USB 2 0 cable External power supply Optional accessories Graphics bo...

Page 52: ...K5902142 04 Nio 5MP 52 Important information...

Page 53: ......

Page 54: ...www barco com K5902142 04 2022 01 10 Barco NV President Kennedypark 35 8500 Kortrijk Belgium...

Reviews: