Encore Presentation System Router Support
Rev 03
- 3 -
Barco MatrixPRO Analog, SDI and DVI routers
o
Pressing the "SAVE" button on the Controller will cause the current state
of the router to be saved as Preset 1 in the router
.
Barco FSN Presentation Switcher
(Ethernet only)
o
When connected to an FSN Presentation Switcher (P/N: R9004627), the
Encore Controller can be setup to recall FSN Presets when Encore Presets
are recalled or independently via User Keys on the Encore Large
Controller
o
IP Port number: 3000
BlackMagic Videohub SDI routers
( Ethernet only)
o
Consult the Blackmagic users guide for help on setting up the router’s IP
address.The RS-422 control on these routers is NOT supported with the
Encore family of controllers. This support was tested on the Smart
Videohub 16x16 running the Blackmagic Videohub Ethernet Protocol
v2.1. This version of the Ethernet Protocol was released with Videohub
4.5.1 software.
o
IP port number: 9990
DVILink 18x18 DVI router
Extron routers
o
TEST COMM defaults the router to 32x32. The router configuration can
not be auto detected by Encore. Just setup the number of inputs and
outputs to match the router.
o
IP Port number: 23
FSR Pathfinder routers
o
Via Serial or Ethernet. When using a serial connection, the cable type
used must be a NULL Modem.
GefenPRO DVI routers
(Ethernet only)
o
IP port number: 23 (default; it may be changed at the router)
o
This support was tested on a GefenPRO 16x16 DVI Matrix router running
Matrix Firmware 6.0.13.
Grass Valley routers
(Ethernet only)
o
IP port number: 12345
ISIS routers
Lantronix UDS-200/UDS-2100 Serial-to-Ethernet device
o
When using Lantronix devices to connect additional routers to the
Controller, make sure the Controller is Powered ON and the Lantronix