Encore Presentation System Router Support                                           

    Rev 03 

 

- 2 - 

Encore Presentation System Router support 

(Code Revision 2.33.00 or higher) 

 

Setup 

 
For serial connection refer to the 

Router User Manual

 for the RS232 pin out of the 

router. Connect the router to the EXT COMM port on the back of the Encore Controller. 
See Appendix A (Pin outs Section) of the 

Encore User Manual

 for information on how 

this port is physically wired. Also see 

Application Note: Encore to Router 

Connections

 distributed with every Encore Presentation Switcher code bundle. 

 
When using ETHERNET to control the router, make sure to set the IP address of the 
router to work with the 192.168.0.xxx range in order to be compatible with the Encore 
Controller network. A good example of an IP address to use would be 192.168.0.245. 
Any 192.168.0.xxx address will work provided it does not conflict with the Controller, 
VPs, other routers and other devices on the network. Consult the Routers users guide for 
help on setting up the router’s IP address. 
 
In the SYSTEM>ROUTER SETUP menu, after choosing the “Protocol”, select 
ETHERNET, LANTRONIX or RS-232, as appropriate, for the “Communication Type”. 
In the "Router Type" field, select "ANALOG" or "SDI" or “DVI” depending on the type 
of router. In the COMM SETUP sub-menu, dial the IP address of the router and the port 
number. The port number is usually 23, the default Ethernet telnet port. If the router 
communicates on a different port the correct selection will be displayed and it will be 
fixed (shown in brackets). Press TEST COMM to establish communication with the 
router. 
 
After returning to the ROUTER SPECIFICATION menu page from COMM SETUP, dial 
in the “Number of Inputs” and “Number of Outputs” to gain full access to the router. 
 

Ethernet Communication 

 
For optimum performance, it is recommended that a 10/100MBit or 100MBit Switch is 
used when connecting the Encore Controller to Video Processing gear and routers 
 

Routers and other Devices Supported 
 

 

AutoPatch routers

 

o

 

Via a direct straight through serial cable to the Encore Controller EXT 
COMM port. Ethernet connection is only supported via the Lantronix 
device. 

o

 

Only level 0; only one connection type (Analog, DVI or SDI). Mixed 
configurations are not supported 

 

 

Barco MatrixPRO-II Analog and 3G SDI and DVI routers 

(Ethernet Only) 

o

 

IP port number: 23 