User’s manual
B
ARCO
W
ALL
C
ONTROL
M
ANAGER
OVD/KVD/IVD
R591337
Page 1: ...User s manual BARCO WALL CONTROL MANAGER OVD KVD IVD R591337...
Page 2: ...Title BARCO WALL CONTROL MANAGER OVD KVD IVD User s Manual ID no R591337 Revision 04 Date March 2016 Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 04 March 2016 __________...
Page 3: ...software on the date of commissioning at the latest 30 days after the transfer of risks In the event of justified notice of complaint BARCO can repair the fault or provide a replacement at its own dis...
Page 4: ...721 6201 298 E mail docu de bcd barco com Web www barcocontrolrooms com From Date Please correct the following points in this documentation R591337 page wrong correct Barco Barco Wall Control Manager...
Page 5: ...22 4 3 Green BCM Services 23 4 4 Admin 24 4 5 System 26 4 5 1 Settings 26 4 5 2 System Time 27 4 6 Network 28 4 7 Wall DHCP 29 4 8 Devices 31 4 9 Remote Power Supply 31 5 Barco Wall Control Manager C...
Page 6: ...8 1 Configuration for startup 59 8 2 Configuration for shutdown 60 8 2 1 User account 60 8 2 2 Installation of an SSH server 61 9 Contact 69 Barco Barco Wall Control Manager OVD KVD IVD R591337 user m...
Page 7: ...d typographic styles and symbols Safety information is provided concerning the operation of computer systems from Barco Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 04 Mar...
Page 8: ...of this manual all hyperlinks appear teal Courier Names of files and parts from programs are printed in the Courier font Courier bold Inputs you are supposed to do from the keyboard are printed in Cou...
Page 9: ...ient application to manage and control Barco large display walls The server runs on dedicated hardware the Green BCM The Green BCM is a wall router and the gateway to launch the client application Bar...
Page 10: ......
Page 11: ...IENT interface comes with the fixed IP address 192 168 10 1 and is set for manual configuration The net work configuration of the CLIENT interface allows integrating the Green BCM into the customer ne...
Page 12: ...f the display the serial number is used which is unique for the display and constant over life time LAN1 of the display is connected to the WALL interface of the Green BCM Box This is the only support...
Page 13: ...dresses are assigned in the sequence the devices are connected to the network If you want to control the IP address assigment switch on the respective devices one by one in the desired sequence The as...
Page 14: ...the page Wall DHCP of Green BCM can get a permanent IP address Permanent IP addresses are in the range 172 29 10 x Click the checkbox es to select the desired device s Click on Permanent The device wi...
Page 15: ...table This allows entering the MAC address and the IP address from scratch The command Delete removes a record from the permanent IP table Add and Delete affect the table on the web page only The ent...
Page 16: ...static IP address in the same address range e g 192 168 10 2 Connect a PC to the CLIENT interface of Green BCM via a network cable Make sure that the PC is running Windows 7 Select Control Panel Netw...
Page 17: ...w Now the PC Laptop is properly connected to the CLIENT interface of Green BCM and can communicate with Green BCM for example assigning permanent IP addresses to the projection modules cf Permanent IP...
Page 18: ...w static IP address is in a different address range than the previous one the PC Laptop won t be able to connect to Green BCM any longer To re establish connection the IP address of the PC Laptop also...
Page 19: ...nables communication to the WALL network via the CLIENT interface Every PC Laptop connected to the CLIENT interface of Green BCM and knowing the IP address of the CLIENT interface of Green BCM can con...
Page 20: ......
Page 21: ...ce Connect a PC Laptop to one of the LAN interfaces of Green BCM Launch Internet Explorer In its address bar enter the URL of the Green BCM http ip address If connected to the WALL interface the IP ad...
Page 22: ...plays it needs to be version 6 or higher Click on the link Start Green BCM Client The Green BCM client application runs in a web browser For best look and feel use Mozilla Firefox Barco Barco Wall Con...
Page 23: ...ly starts the service Green BCM Database Reset Saves a copy of the database and then clears the database the data base is overwritten with an empty database A second go of Reset will thus copy the new...
Page 24: ...ialog pops up Enter valid credentials Tasks Green BCM Services Show Shows the services running on Green BCM see screen below Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 0...
Page 25: ...nd Start offered on the BMC web page activated after the Standby command has been sent The command to put the display wall into standby needs to be con firmed When confirmed the Green BCM box and all...
Page 26: ...figure the WSM 200 you need to download the Key Click on the link For configuration of the WSM 200 see 8 Controlling a WSM 200 with gBCM The host name is subject to following restrictions Host name li...
Page 27: ...vers can be defined by entering their IP address Select the required time zone to transform time information either from NTP server or from the Green BCM hardware clock from UTC into a local time zone...
Page 28: ...ly activates the settings and restarts the DHCP server i e it writes the permanent IP address es into its configuration table and also updates the table with the short term IP addresses if a device ha...
Page 29: ...to assign a permanent IP ad dress to a device The MAC address of the device and the assigned IP address are stored as a pair in the configu ration table of the Green BCM DHCP server In principle all...
Page 30: ...ess or IP address respectively the checkbox needs to be ticked when clicking the Apply button To activate any changes in the permanent IP table requires To restart the DHCP server click Apply To resta...
Page 31: ...page Active Wall Devices shows only devices controlled by Green BCM 4 9 Remote Power Supply This link and the navigaton bar and the related page is only available if the LCD displays have been upgrade...
Page 32: ...ber of power supplies per back plane the output voltage the output current the tem perature and the fan health Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 04 March 2016 _...
Page 33: ...led 5 2 Launching the client application The Barco Wall Control Manager Client application can be launched by any Windows PC connected to the Green BCM Click on BCM Client to start the client applicat...
Page 34: ...t of a display fine tuning SenseX Brightness adjustment of the entire wall Selection of color temperature of the entire wall Switching a display on idle Switching the video wall on idle Selecting the...
Page 35: ...hecked until you are familiar with the BCM client This setting is stored cookies based for the current host user and browser There is no browser or BCM user specific storage Use CTRL mouse wheel for b...
Page 36: ...lays when the display wall is one row in height Use the spin buttons to set width and height the fields are not editable Click on the button next to the wall name to add this wall Barco Barco Wall Con...
Page 37: ...ject ID owner city and country Click OK Continue to the next step The next step links the cell in the grid to a display represented by its serial number Barco Barco Wall Control Manager OVD KVD IVD R5...
Page 38: ...in the wall subnet The serial numbers of all found devices are listed gray Since there are two LAN interfaces and thus two MAC addresses the serial number of the display is used as identifier The fir...
Page 39: ...he grid show a green tick i e every cell is linked to a display To unassign a device click into the respective cell in the grid Subsequently push the button Unassign Click Done If IP Readdressing is t...
Page 40: ...ing info dialog it can take several minutes depending on the amount of displays before the new IP addresses have been assigned During the readdresseing the displays modules on the wall dashboard will...
Page 41: ...the table you see a menu icon Click to open a list box which allows selecting unselecting the properties shown in the System Info The following properties are available Device Type IP Connection State...
Page 42: ...n in the System Info Since the information next to the display shows the Display Type Display IP Serial Number Operation State Connection State these properties are not available in the System Info ta...
Page 43: ...ed availability check which will con tinue until a connection can be established again It s not necessary to trigger a reconnect manually if the disconnect takes more than 200s A red error sausage ind...
Page 44: ......
Page 45: ...layed In case the browser window is too small the control panel will overlap the wall grid Please note that the minimum resolution for the client is 1280x800 pixels The display wall no matter how many...
Page 46: ...o Overview if you visited the dashboard of the display starting from Control screen you will then be redirected to the Control screen of the display wall Clicking Back to Overview if dashboard has bee...
Page 47: ...shows a pigeon blue border or a selected display to idle if running and vice versa To select a display click into the display the display will show a pigeon blue border as visual indicator that it is...
Page 48: ...it to the adjacent displays This is the only way for multi selection No other mouse actions or key strokes are supported Not all controlling actions support multi selection Amongst others multi selec...
Page 49: ...layPort input with HDCP 1 3 up to 300MHz On the Control page you can select the input of the entire wall or of an individual display You can also view and select the currently active input s The mini...
Page 50: ...input only To select a timing for the input or to upload a new timing launch the web interface of the display go to the HOME page and select the display This will show the dashboard of the display Cl...
Page 51: ...temperature If Custom is clicked a custom color temperature can be set and the locus distance defined The supported values are indicated The OK button gets only enabled if a valid color temperature h...
Page 52: ...and all properties are updated Display properties are being polled by the server from the display at constant rate in the background This takes around 20 25 secs until all displays and all properties...
Page 53: ...is not adjusted during pushing the slider but only if the set value is fix for 5 seconds Only then the adjustment is triggered Brightness adjustment to the set value is also triggered when navigating...
Page 54: ...ess After pushing the sliders the settings need to be constant for 5 seconds before adjustment to the set value is triggered The adjustment procedure is also triggered when navigating to this page or...
Page 55: ...sired day of the week Click the dropdown Weekly and set the measurement to weekly or daily if desired When time day and repeat have been set click the button to activate the task A task can be schedul...
Page 56: ......
Page 57: ...label In BCM client click Setup on the menu bar The display wall is shown and could be edited Click Next to access the dialog allowing assign unassign a display Make sure that IP Readdressing is check...
Page 58: ...rsion of the new display In case it does not match the version required for the display wall perform a firmware upgrade using the web interface of the display In case you end up with duplicate IP addr...
Page 59: ...nnection to gBCM the Windows firewall is Off 8 1 Configuration for startup To make startup working correctly the BIOS setting of the WSM 200 need to be adjusted Check apply the following settings Tab...
Page 60: ...gure it to run as service 8 2 1 User account On WSM 200 go to Start Control Panel All Control Panel Items User Accounts add Create a user shutdown with password shutdown Control Panel Check Password n...
Page 61: ...cumented on https www itefix net copssh The setup wizard guides through the installation process Copssh requires a dedicated service account You might accept the default settings as suggested by the s...
Page 62: ...el The COPSSH Control Panel features 5 tabs Status Users Configuration SFTP About On the Status tab you can monitor start and stop the service On the Users tab you need to add the user shutdown cf 8 2...
Page 63: ...BCM Click Add to start the Copssh User Activation wizard Enter domain and the user shutdown Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 04 March 2016 ____________________...
Page 64: ...ecked Click Apply to complete adding user shutdown Navigate to the tab SFTP Make sure to remove the tick in Enabled to disable SFTP Click Apply To make the changes effective the service needs to be re...
Page 65: ...should now look like this Click on Keys to import the key downloaded from the gBCM web page cf 4 5 System Click Import Barco Barco Wall Control Manager OVD KVD IVD R591337 user manual Revision 04 Marc...
Page 66: ...r the new settings to become active the WSM 200 needs to be restarted When the WSM 200 is up and running again launch the COPSSH Control Panel cf 8 2 2 1 COPSSH Control Panel On Status tab click the b...
Page 67: ...alled Openssh SSHD You might also start stop the service via Windows Services Start Control Panel Administrative Tools Component Services Barco Barco Wall Control Manager OVD KVD IVD R591337 user manu...
Page 68: ......
Page 69: ...trijk BE0473191041 Visit Barco at http www barco com For Professional Support visit http www barco com support For Sales or other Contact information visit http www barco com contact regional offices...